enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. AC power - Wikipedia

    en.wikipedia.org/wiki/AC_power

    Reactive power does not do any work, so it is represented as the imaginary axis of the vector diagram. Active power does do work, so it is the real axis. The unit for power is the watt (symbol: W). Apparent power is often expressed in volt-amperes (VA) since it is the product of RMS voltage and RMS current. The unit for reactive power is var ...

  3. Power factor - Wikipedia

    en.wikipedia.org/wiki/Power_factor

    Power flow calculated from AC voltage and current entering a load having a zero power factor (ϕ = 90°, cos(ϕ) = 0).The blue line shows the instantaneous power entering the load: all of the energy received during the first (or third) quarter cycle is returned to the grid during the second (or fourth) quarter cycle, resulting in an average power flow (light blue line) of zero.

  4. Electric power - Wikipedia

    en.wikipedia.org/wiki/Electric_power

    Electric power is transmitted by overhead lines like these, and also through underground high-voltage cables. Electric power is the rate of transfer of electrical energy within a circuit. Its SI unit is the watt, the general unit of power, defined as one joule per second. Standard prefixes apply to watts as with other SI units: thousands ...

  5. Power-flow study - Wikipedia

    en.wikipedia.org/wiki/Power-flow_study

    In power engineering, the power-flow study, or load-flow study, is a numerical analysis of the flow of electric power in an interconnected system. A power-flow study usually uses simplified notations such as a one-line diagram and per-unit system, and focuses on various aspects of AC power parameters, such as voltages, voltage angles, real power and reactive power.

  6. Maximum power transfer theorem - Wikipedia

    en.wikipedia.org/wiki/Maximum_power_transfer_theorem

    The red curve shows the power in the load, normalized relative to its maximum possible. The dark blue curve shows the efficiency η. The efficiency η is the ratio of the power dissipated by the load resistance R L to the total power dissipated by the circuit (which includes the voltage source's resistance of R S as well as R L):

  7. Alpha–beta transformation - Wikipedia

    en.wikipedia.org/wiki/Alpha–beta_transformation

    Another way to understand this is that the equation + + = defines a plane in a euclidean three coordinate space. The alpha-beta coordinate space can be understood as the two coordinate space defined by this plane, i.e. the alpha-beta axes lie on the plane defined by I a + I b + I c = 0 {\displaystyle I_{a}+I_{b}+I_{c}=0} .

  8. Capability curve - Wikipedia

    en.wikipedia.org/wiki/Capability_curve

    In practice, the prime mover (a power source that drives the generator) is designed for less active power than the generator is capable of (due to the fact that in real life generator always has to deliver some reactive power [2]), so a prime mover limit (a vertical dashed line on the illustration) changes the constraints somewhat (in the ...

  9. Electrical reactance - Wikipedia

    en.wikipedia.org/wiki/Electrical_reactance

    In electrical circuits, reactance is the opposition presented to alternating current by inductance and capacitance. [1] Along with resistance, it is one of two elements of impedance; however, while both elements involve transfer of electrical energy, no dissipation of electrical energy as heat occurs in reactance; instead, the reactance stores energy until a quarter-cycle later when the energy ...