Search results
Results from the WOW.Com Content Network
The integration of a flux over an area gives the volumetric flow rate. The SI unit is cubic metres per second (m 3 /s). Another unit used is standard cubic centimetres per minute (SCCM). In US customary units and imperial units, volumetric flow rate is often expressed as cubic feet per second (ft 3 /s) or gallons per minute (either US or ...
The relationship between gallons per minute (gpm) and fixture unit is not constant, but varies with the number of fixture units. For example, 1000 FU is equivalent to 220 US gallons per minute (0.014 m 3 /s) while 2000 FU represents only 330 US gallons per minute (0.021 m 3 /s), about 1.5 times the flow rate.
Cubic metre per second or cubic meter per second in American English (symbol m 3 ⋅ s −1 or m 3 /s) is the unit of volumetric flow rate in the International System of Units (SI). It corresponds to the exchange or movement of the volume of a cube with sides of one metre (39.37 in) in length (a cubic meter, originally a stere) each second.
cubic centimetre of atmosphere; standard cubic centimetre: cc atm; scc ≡ 1 atm × 1 cm 3 = 0.101 325 J: cubic foot of atmosphere; standard cubic foot: cu ft atm; scf ≡ 1 atm × 1 ft 3 = 2.869 204 480 9344 × 10 3 J: cubic foot of natural gas: ≡ 1000 BTU IT = 1.055 055 852 62 × 10 6 J: cubic yard of atmosphere; standard cubic yard: cu yd ...
References will be made to "actual" flow rate through a meter and "standard" or "base" flow rate through a meter with units such as acm/h (actual cubic meters per hour), sm 3 /sec (standard cubic meters per second), kscm/h (thousand standard cubic meters per hour), LFM (linear feet per minute), or MMSCFD (million standard cubic feet per day ...
The standard liter per minute (SLM or SLPM) is a unit of (molar or) mass flow rate of a gas at standard conditions for temperature and pressure (STP), which is most commonly practiced in the United States, whereas European practice revolves around the normal litre per minute (NLPM). [1]
For some usage examples, consider the conversion of 1 SCCM to kg/s of a gas of molecular weight , where is in kg/kmol. Furthermore, consider standard conditions of 101325 Pa and 273.15 K, and assume the gas is an ideal gas (i.e., =).
For example, a mass flow rate of 1,000 kg/h of air at 1 atmosphere of absolute pressure is 455 SCFM when defined at 32 °F (0 °C) but 481 SCFM when defined at 60 °F (16 °C). Due to the variability of the definition and the consequences of ambiguity, it is best engineering practice to state what standard conditions are used when communicating ...