enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Power plant efficiency - Wikipedia

    en.wikipedia.org/wiki/Power_plant_efficiency

    A heat rate value of 4 MJ/MJ gives an efficiency factor of 25%. For other units, make sure to use a corresponding conversion factor for the units. For example, if using Btu/kWh, use a conversion factor of 3,412 Btu per kWh to calculate the efficiency factor. For example, if the heat rate is 10,500 Btu/kWh, the efficiency is 32.5% (since 3,412 ...

  3. Energy conversion efficiency - Wikipedia

    en.wikipedia.org/wiki/Energy_conversion_efficiency

    For a water electrolysis unit operating at a constant temperature of 25 °C without the input of any additional heat energy, electrical energy would have to be supplied at a rate equivalent of the enthalpy (heat) of reaction or 285.830 kJ (0.07940 kWh) per gram mol of water consumed. [6] It would operate at a cell voltage of 1.48 V.

  4. Rate of heat flow - Wikipedia

    en.wikipedia.org/wiki/Rate_of_heat_flow

    The rate of heat flow is the amount of heat that is transferred per unit of time in some material, usually measured in watts (joules per second). Heat is the flow of thermal energy driven by thermal non-equilibrium, so the term 'heat flow' is a redundancy (i.e. a pleonasm). Heat must not be confused with stored thermal energy, and moving a hot ...

  5. British thermal unit - Wikipedia

    en.wikipedia.org/wiki/British_thermal_unit

    A typical coal-fired power plant works at 10,500 Btu/kWh (3.1 kWh/kWh), an efficiency of 32–33%. [25] The centigrade heat unit (CHU) is the amount of heat required to raise the temperature of one pound (0.45 kg) of water by one Celsius degree. It is equal to 1.8 Btu or 1,899 joules. [26]

  6. Watt - Wikipedia

    en.wikipedia.org/wiki/Watt

    The watt (symbol: W) is the unit of power or radiant flux in the International System of Units (SI), equal to 1 joule per second or 1 kg⋅m 2 ⋅s −3. [1] [2] [3] It is used to quantify the rate of energy transfer.

  7. Kilowatt-hour - Wikipedia

    en.wikipedia.org/wiki/Kilowatt-hour

    A kilowatt is a unit of power (rate of flow of energy per unit of time). A kilowatt-hour is a unit of energy. Kilowatt per hour would be a rate of change of power flow with time. Work is the amount of energy transferred to a system; power is the rate of delivery of energy. Energy is measured in joules, or watt-seconds.

  8. Thermal efficiency - Wikipedia

    en.wikipedia.org/wiki/Thermal_efficiency

    So, for a boiler that produces 210 kW (or 700,000 BTU/h) output for each 300 kW (or 1,000,000 BTU/h) heat-equivalent input, its thermal efficiency is 210/300 = 0.70, or 70%. This means that 30% of the energy is lost to the environment. An electric resistance heater has a thermal efficiency close to 100%. [8]

  9. Heat transfer coefficient - Wikipedia

    en.wikipedia.org/wiki/Heat_transfer_coefficient

    The heat transfer coefficient has SI units in watts per square meter per kelvin (W/(m 2 K)). The overall heat transfer rate for combined modes is usually expressed in terms of an overall conductance or heat transfer coefficient, U. In that case, the heat transfer rate is: ˙ = where (in SI units):