A standard 12-lead ECG report (an electrocardiograph) shows a 2.5 second tracing of each of the twelve leads. The tracings are most commonly arranged in a grid of four columns and three rows. The first column is the limb leads (I, II, and III), the second column is the augmented limb leads (aVR, aVL, and aVF), and the last two columns are the ...
Wolff–Parkinson–White syndrome (WPWS) is a disorder due to a specific type of problem with the electrical system of the heart involving an accessory pathway able to conduct electrical current between the atria and the ventricles, thus bypassing the atrioventricular node.
There are 6 different sinus arrhythmia. [1] [2]A normal heart should have a normal sinus rhythm, this rhythm can be identified by a ventricular rate of 60-100 bpm, at a regular rate, with a normal PR interval (0.12 to 0.20 second) and a normal QRS complex (0.12 second and less).
In humans, for an ECG to be described as showing a sinus rhythm, the shape of the P wave in each of the 12 standard ECG leads should be consistent with a "typical P vector" of +50° to +80°. [2] This means that the P wave should be: always positive in lead I, lead II, and aVF; always negative in lead aVR
Schematic representation of a normal sinus rhythm ECG wave. Diagram showing how the polarity of the QRS complex in leads I, II, and III can be used to estimate the heart's electrical axis in the frontal plane. The QRS complex is the combination of three of the graphical deflections seen on a typical electrocardiogram (ECG or EKG). It is usually ...
Pulseless electrical activity (PEA) is a form of cardiac arrest in which the electrocardiogram shows a heart rhythm that should produce a pulse, but does not.Pulseless electrical activity is found initially in about 20% of out-of-hospital cardiac arrests [1] and about 50% of in-hospital cardiac arrests.
The heart rhythm must originate above the ventricles (i.e., sinoatrial node, atria or atrioventricular node) to activate the conduction system at the correct point. The QRS duration must be more than 100 ms (incomplete block) or more than 120 ms (complete block). [9]
Multifocal atrial tachycardia is characterized by an electrocardiogram (ECG) strip with three or more discrete P wave morphologies in the same lead, not including that originating from the sinoatrial node, plus tachycardia, which is a heart rate exceeding 100 beats per minute (although some suggest using a threshold of 90 beats per minute ...