Search results
Results from the WOW.Com Content Network
Industrial pressure switches may have a calibrated scale and pointer to show the set point of the switch. A pressure switch will have a hysteresis, that is, a differential range around its setpoint, known as the switch's deadband, inside which small changes of pressure do not influence the state of the contacts. Some types allow adjustment of ...
The program features include time schedules, set points, controllers, logic, timers, trend logs, and alarms. The unit controllers typically have analog and digital inputs that allow measurement of the variable (temperature, humidity, or pressure) and analog and digital outputs for control of the transport medium (hot/cold water and/or steam ...
A manifold pressure regulating shut-off valve (MPRSOV) restricts the flow as necessary to maintain the desired pressure for downstream systems. A certain minimum supply pressure is needed to drive the air through the system, but it is desired to use as low a supply pressure as possible, because the energy the engine uses to compress the bleed ...
Such a system contains a boiler, furnace, or heat pump to heat water, steam, or air in a central location such as a furnace room in a home, or a mechanical room in a large building. The heat can be transferred by convection, conduction, or radiation. Space heaters are used to heat single rooms and only consist of a single unit.
A typical nominal regulated gauge pressure from a medical oxygen regulator is 3.4 bars (50 psi), for an absolute pressure of approximately 4.4 bar and a pressure ratio of about 4.4 without back pressure, so they will have choked flow in the metering orifices for a downstream (outlet) pressure of up to about 2.3 bar absolute.
Pneumatically actuated shut down valve A diagram of the internal components of a safety shutoff valve. When this type of valve is tripped, the flow is quickly stopped and an indicator disc tells the operator that the electrical circuit has been opened by a failure somewhere in the system
In a water boiler, draft is the difference between atmospheric pressure and the pressure existing in the furnace or flue gas passage. [1] Draft can also be referred to as the difference in pressure in the combustion chamber area which results in the motion of the flue gases and the air flow.
In natural gas furnaces, water heaters, and room heating systems, a safety cut-off switch is normally included so that the gas supply to the pilot and heating system is shut off by an electrically operated valve if the pilot light goes out. This cut-off switch usually detects the pilot light in one of several ways: A flame rectification device. [2]