Search results
Results from the WOW.Com Content Network
McQuay's President, from 1933 until his death in June of 1957, was Roy Jay Resch, originally of Cleveland, Ohio. During 1941 to 1945, McQuay manufacturing facilities were converted to support the U.S. war effort. McQuay designed and manufactured self-sealing fuel tanks and extended bomb release shackles for the Doolittle Tokyo Raider's B-25s.
However, in November 2013, the Daikin-McQuay group was again rebranded as Daikin Applied, [9] ending 80 years of business for the McQuay name in the United States. Meanwhile, the McQuay brand continues to be used in China and Hong Kong. [10] In the filtration realm, Daikin acquired American Air Filter (AAF) in 2007, [11] and Flanders in 2016. [12]
The CLTD/CLF/SCL (cooling load temperature difference/cooling load factor/solar cooling load factor) cooling load calculation method was first introduced in the 1979 ASHRAE Cooling and Heating Load Manual (GRP-158) [1] The CLTD/CLF/SCL Method is regarded as a reasonably accurate approximation of the total heat gains through a building envelope ...
A liquid (glycol based) chiller with an air cooled condenser on the rooftop of a medium size commercial building. In air conditioning systems, chilled coolant, usually chilled water mixed with ethylene glycol, from a chiller in an air conditioning or cooling plant is typically distributed to heat exchangers, or coils, in air handlers or other types of terminal devices which cool the air in ...
[2] [3] Air conditioning is a member of a family of systems and techniques that provide heating, ventilation, and air conditioning (HVAC). [4] Heat pumps are similar in many ways to air conditioners, but use a reversing valve to allow them both to heat and to cool an enclosed space. [5]
The effects a variable flow system had on the selection of control valves, was not initially realized. A control valve was selected by using the same K v calculation, and the bypass on a 3-port valve blocked, giving a 2-port valve. It was not that simple. This is because our K v calculation K v = flow rate [m 3 /h] / ΔP [bar
Propylene glycol plays a significant role in the application of a glycol chiller. For cooling in brewing, there are few processes where decreasing or maintaining temperature are important - like crash cooling a beer after fermentation, or keeping a steady temperature during fermentation (which generates heat), or cooling the wort after an ...
These motors are sometimes called DC motors, sometimes EC motors and occasionally DC/EC motors. DC stands for direct current and EC stands for electronically commutated.. DC motors allow the speed of the fans within a fan coil unit to be controlled by means of a 0-10 Volt input control signal to the motor/s, the transformers and speed switches associated with AC fan coils are not required.