Catchments are commonly used to determine sprinkler DU and one must be reminded that data collection most often occurs above grade and above the root zone where plant uptake normally occurs. Many factors may affect water distribution or redistribution between catchment plane and root zone; slope, plant canopy, thatch, mulch, infiltration rate ...
A water flow test, also known as a hydrant flow test, [1] is a way to measure the water supply available at a building site, usually for the purposes of installing a water based fire protection system (fire sprinkler system). The most common test involves measuring the flow of water flowing out of a municipal fire hydrant (measured in litres or ...
A sprinkler system having pressurized air (rather than water) in the distribution pipes until a heat-activated sprinkler head opens and releases the stored air pressure, which in turn opens the main water valve (and possibly an accelerator valve) to flow water to the open sprinkler(s); used where the protected premises are not heated during ...
The NFPA 72 "covers the application, installation, location, performance, inspection, testing, and maintenance of fire alarm systems, supervising station alarm systems, public emergency alarm reporting systems, fire warning equipment and emergency communications systems (ECS), and their components."
The main standard that governs fire pump fixed-place installations in North America is the National Fire Protection Association's NFPA 20 Standard for the Installation of Stationary Fire Pumps for Fire Protection. [1] Fire pumps are powered most commonly by an electric motor or a diesel engine, or, occasionally a steam turbine.
Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!
Comparison of a regular sprinkler (1) and a reverse sprinkler (2) A Feynman sprinkler, also referred to as a Feynman inverse sprinkler or reverse sprinkler, is a sprinkler-like device which is submerged in a tank and made to suck in the surrounding fluid. The question of how such a device would turn was the subject of an intense and remarkably ...
V is velocity (in ft/s for US customary units, in m/s for SI units) k is a conversion factor for the unit system (k = 1.318 for US customary units, k = 0.849 for SI units) C is a roughness coefficient; R is the hydraulic radius (in ft for US customary units, in m for SI units) S is the slope of the energy line (head loss per length of pipe or h ...