enow.com Web Search

  1. Ads

    related to: transformer kva size chart for appliances and equipment pictures and meaning

Search results

  1. Results from the WOW.Com Content Network
  2. Distribution transformer - Wikipedia

    en.wikipedia.org/wiki/Distribution_transformer

    Distribution transformers typically have ratings less than 200 kVA, [3] although some national standards allow units up to 5000 kVA to be described as distribution transformers. Since distribution transformers are energized 24 hours a day (even when they don't carry any load), reducing iron losses is vital in their design.

  3. Electric power distribution - Wikipedia

    en.wikipedia.org/wiki/Electric_power_distribution

    Some large European appliances may be powered by three-phase power, such as electric stoves and clothes dryers. A ground connection is normally provided for the customer's system as well as for the equipment owned by the utility. The purpose of connecting the customer's system to ground is to limit the voltage that may develop if high voltage ...

  4. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    The line to neutral voltage is half the line-to-line voltage. Lighting and small appliances may be connected between a line wire and the neutral. Higher-power appliances, such as cooking equipment, space heating, water heaters, clothes dryers, air conditioners and electric vehicle charging equipment, are connected to the two line conductors.

  5. Buck–boost transformer - Wikipedia

    en.wikipedia.org/wiki/Buck–boost_transformer

    Buck–boost transformers can be used to power low voltage circuits including control, lighting circuits, or applications that require 12, 16, 24, 32 or 48 volts, consistent with the design's secondaries. The transformer is connected as an isolating transformer and the nameplate kVA rating is the transformer’s capacity. [2]

  6. Transformer types - Wikipedia

    en.wikipedia.org/wiki/Transformer_types

    Transformer oil is flammable, so oil-filled transformers inside a building are installed in vaults to prevent spread of fire and smoke from a burning transformer. Some transformers were built to use fire-resistant PCBs , but because these compounds persist in the environment and have adverse effects on organisms, their use has been discontinued ...

  7. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    A "delta" (Δ) connected transformer winding is connected between phases of a three-phase system. A "wye" (Y) transformer connects each winding from a phase wire to a common neutral point. A single three-phase transformer can be used, or three single-phase transformers. In an "open delta" or "V" system, only two transformers are used.

  8. Pad-mounted transformer - Wikipedia

    en.wikipedia.org/wiki/Pad-mounted_transformer

    Pad-mounted transformers are made in power ratings from around 15 to around 5000 kVA and often include built-in fuses and switches. Primary power cables may be connected with elbow connectors, which can be operated when energized using a hot stick and allows for flexibility in repair and maintenance.

  9. Single-wire earth return - Wikipedia

    en.wikipedia.org/wiki/Single-wire_earth_return

    The transformers are usually rated at 5 kVA, 10 kVA, and 25 kVA. The load densities are usually below 0.5 kVA per kilometer (0.8 kVA per mile) of line. Any single customer's maximum demand will typically be less than 3.5 kVA, but larger loads up to the capacity of the distribution transformer can also be supplied.

  1. Ads

    related to: transformer kva size chart for appliances and equipment pictures and meaning