enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Aluminium-conductor steel-reinforced cable - Wikipedia

    en.wikipedia.org/wiki/Aluminium-conductor_steel...

    An ACSR conductor can in part be denoted by its stranding, for example, an ACSR conductor with 72 aluminium strands with a core of 7 steel strands will be called 72/7 ACSR conductor. [ 3 ] [ 4 ] [ 5 ] Cables generally range from #6 AWG ("6/1" – six outer aluminum conductors and one steel reinforcing conductor) to 2167 kcmil ("72/7 ...

  3. Neher–McGrath method - Wikipedia

    en.wikipedia.org/wiki/Neher–McGrath_method

    J. H. Neher and M. H. McGrath were two electrical engineers who wrote a paper in 1957 about how to calculate the capacity of current (ampacity) of cables. [1] The paper described two-dimensional highly symmetric simplified calculations which have formed the basis for many cable application guidelines and regulations.

  4. Circular mil - Wikipedia

    en.wikipedia.org/wiki/Circular_mil

    The formula to calculate the area in circular mil for any given AWG (American Wire Gauge) size is as follows.represents the area of number AWG. = (() /) For example, a number 12 gauge wire would use =:

  5. Dynamic line rating for electric utilities - Wikipedia

    en.wikipedia.org/wiki/Dynamic_line_rating_for...

    They are based on "steady-state (equilibrium) ampacity" calculations. Emergency ratings are based on transient equations and models: they provide permissible overload ratings for a short and adjustable time (typically 5 to 30 minutes). Forecasting methods have been developed to determine intraday and day-ahead ampacity forecasts.

  6. Aerial bundled cable - Wikipedia

    en.wikipedia.org/wiki/Aerial_bundled_cable

    Aerial bundled cables (also aerial bundled conductors or simply ABC) are overhead power lines using several insulated phase conductors bundled tightly together, usually with a bare neutral conductor. This contrasts with the traditional practice of using uninsulated conductors separated by air gaps.

  7. Ampacity - Wikipedia

    en.wikipedia.org/wiki/Ampacity

    For example, the United States National Electrical Code, Table 310.15(B)(16), specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30 °C, the conductor surface temperature allowed to be 75 °C. A single insulated conductor ...

  8. IEC 60228 - Wikipedia

    en.wikipedia.org/wiki/IEC_60228

    Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...

  9. Litz wire - Wikipedia

    en.wikipedia.org/wiki/Litz_wire

    The skin effect and proximity effect cause conductors to exhibit higher resistance to alternating current (AC) than to direct current (DC). Due to the dual inverse nature of the electromagnetic field, the skin effect dominates at frequencies less than about 2 MHz; at higher frequencies, the proximity effect becomes the dominant force, and Litz wire induces more DC losses than solid wire or ...