enow.com Web Search

  1. Ads

    related to: hvac returns in every room at 12 minutes and 15 hours in 3 miles

Search results

  1. Results from the WOW.Com Content Network
  2. Air changes per hour - Wikipedia

    en.wikipedia.org/wiki/Air_changes_per_hour

    [15] [16] For example, to maintain a 15 °C temperature in a certain dwelling about 3.0 kW of heating are required at 0 ACH (no heat loss due to warmed air leaving the dwelling, instead heat is lost due to conduction or radiation), 3.8 kW at 1 ACH and 4.5 kW are required at 2 ACH. [15] The use of roof space for heating or cooling was seen as ...

  3. Infiltration (HVAC) - Wikipedia

    en.wikipedia.org/wiki/Infiltration_(HVAC)

    In cold climates, with a 15 MPH wind, residences often have air exchange rates of 1.0 to 1.5 ACHs, far in excess of the ventilation air needs and are thus called loose construction. It is very easy to reduce infiltration rates to less than 1.0 ACH. Smoke candles and blower-door tests can help identify less-than-obvious leaks.

  4. Room air distribution - Wikipedia

    en.wikipedia.org/wiki/Room_air_distribution

    Displacement ventilation systems supply air directly to the occupied zone.The air is supplied at low velocities to cause minimal induction and mixing. This system is used for ventilation and cooling of large high spaces, such as auditorium and atria, where energy may be saved if only the occupied zone is treated rather than trying to control the conditions in the entire space.

  5. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The CLTD/CLF/SCL (cooling load temperature difference/cooling load factor/solar cooling load factor) cooling load calculation method was first introduced in the 1979 ASHRAE Cooling and Heating Load Manual (GRP-158) [1] The CLTD/CLF/SCL Method is regarded as a reasonably accurate approximation of the total heat gains through a building envelope ...

  6. Underfloor air distribution - Wikipedia

    en.wikipedia.org/wiki/Underfloor_air_distribution

    Conventional overhead mixing systems usually locate both the supply and return air ducts at the ceiling level. Supply air is supplied at velocities higher than typically acceptable for human comfort and the air temperature may be lower, higher, or the same as desired room temperature depending on the cooling/heating load.

  7. Register (air and heating) - Wikipedia

    en.wikipedia.org/wiki/Register_(air_and_heating)

    During winter months, for example, an air conditioning register can be closed to prevent cold air from being pulled from the room. This allows the hot air to mix more completely with the cold air in the room, improving the efficiency of the HVAC system. [7] (The return should be efficient enough to draw off the cooler air.) [10] [11]

  8. Constant air volume - Wikipedia

    en.wikipedia.org/wiki/Constant_air_volume

    Constant air volume (CAV) is a type of heating, ventilating, and air-conditioning system. In a simple CAV system, the supply air flow rate is constant, but the supply air temperature is varied to meet the thermal loads of a space. [1] Most CAV systems are small, and serve a single thermal zone.

  9. HVAC control system - Wikipedia

    en.wikipedia.org/wiki/HVAC_control_system

    HVAC (Heating, Ventilation and Air Conditioning) equipment needs a control system to regulate the operation of a heating and/or air conditioning system. [1] Usually a sensing device is used to compare the actual state (e.g. temperature) with a target state. Then the control system draws a conclusion what action has to be taken (e.g. start the ...

  1. Ads

    related to: hvac returns in every room at 12 minutes and 15 hours in 3 miles