Search results
Results from the WOW.Com Content Network
Partial stroke testing (or PST) is a technique used in a control system to allow the user to test a percentage of the possible failure modes of a shut down valve without the need to physically close the valve. PST is used to assist in determining that the safety function will operate on demand.
Proof test - A manual test that allows the operator to determine whether the valve is in the "as good as new" condition by testing for all possible failure modes and requires a plant shutdown Diagnostic Test - An automated on-line test that will detect a percentage of the possible failure modes of the shutdown valve.
A manifold pressure regulating shut-off valve (MPRSOV) restricts the flow as necessary to maintain the desired pressure for downstream systems. A certain minimum supply pressure is needed to drive the air through the system, but it is desired to use as low a supply pressure as possible, because the energy the engine uses to compress the bleed ...
One example of SIS is a temperature sensor that provides a signal to a controller, which compares the sensed process temperature to the desired temperature setpoint and sends a signal to an emergency on-off valve actuator which stops the flow of heating fluid to the process if the process temperature is exceeded by an unsafe margin.
The test involves filling the vessel or pipe system with a liquid, usually water, which may be dyed to aid in visual leak detection, and pressurization of the vessel to the specified test pressure. Pressure tightness can be tested by shutting off the supply valve and observing whether there is a pressure loss.
A high-integrity pressure protection system (HIPPS) is a type of safety instrumented system (SIS) designed to prevent over-pressurization of a plant, such as a chemical plant or oil refinery. The HIPPS will shut off the source of the high pressure before the design pressure of the system is exceeded, thus preventing loss of containment through ...
Valve leakage refers to flow through a valve which is set in the 'off' state. The importance of valve leakage depends on what the valve is controlling. For example, a dripping tap is less significant than a leak from a six-inch pipe carrying high-pressure radioactive steam.
A relief valve DN25 on cooling water pipe from heat exchanger Schematic diagram of a conventional spring-loaded pressure relief valve. A relief valve or pressure relief valve (PRV) is a type of safety valve used to control or limit the pressure in a system; excessive pressure might otherwise build up and create a process upset, instrument or equipment failure, explosion, or fire.