A "two wire" version for local service, a four wire version for toll service. Two/four wire versions were also available as was a TOPS variant that was used to provide Operator services. The first four wire switch (four wire-tops, i.e., it provided toll switching and operator services) was placed in service in Thunder Bay circa 1972.
Connection was made via a crossbar switch. A SP1 2-wire variant was also available that provided Centrex services. A version of the SP-1 ESS that could provide both 2 & 4 wire services was also built. The first instance was installed in Vegreville Alberta in 1976 or 1977. SP1 4-Wire (Toll)
The A leg goes to pin 5 and the B leg to pin 2 in the master socket. (Although all equipment will work with a reversed line, so a reverse wired socket is not strictly a fault.) When current is flowing on the line, the B leg voltage collapses to nearer ground and the A leg voltage moves nearer to the B leg voltage. The exact voltage drop is a ...
Grid units will always be energized on the top side from the many other units tied into the grid. A spot network is 2 or more transformers dedicated to a single customer. The grid feeds multiple customers. A network protector has a circuit breaker set of contacts and a controlling protection relay. The components are enclosed in a protective ...
The voice switching fabric plan was similar to that of the earlier 5XB switch in being bidirectional and in using the call-back principle. [clarification needed] [citation needed] The largest full-access matrix switches (the 12A line grids had partial access) in the system, however, were 8x8 rather than 10x10 or 20x16.
Every time the contacts of an electromechanical switch, relay or contactor are opened or closed, there is a certain amount of contact wear. If the contact is cycling without electricity (dry), the impact of the contact electrodes a slightly deformed by the resulting cold forging. [1]
Leg as in "hot leg" refers to one of multiple hot conductors in an electrical system. The most common residential and small commercial service in Canada and the U.S., single split-phase, 240 V, features a neutral and two hot legs, 240 V to each other, and 120 V each to the neutral. The most common three-phase system will have three hot legs ...
A receptacle with a bootleg ground. In building wiring installed with separate neutral and protective ground bonding conductors (a TN-S network), a bootleg ground (or a false ground) is a connection between the neutral side of a receptacle or light fixture and the ground lug or enclosure of the wiring device.