ANSI/ASHRAE/IES Standard 90.1: Energy Standard for Buildings Except Low-Rise Residential Buildings is an American National Standards Institute (ANSI) standard published by ASHRAE and jointly sponsored by the Illuminating Engineering Society (IES) that provides minimum requirements for energy efficient designs for buildings except for low-rise residential buildings (i.e. single-family homes ...
ASHRAE 90.1 follows a similar path of development and revision. [6] Though ASHRAE 90.1 is revised and published every three years just like the IECC, people can submit interim revisions at any time within this period. [5] ASHRAE has a standards committee that manages the process, and votes on the final versions of the energy code. [5]
The CLTD/CLF/SCL (cooling load temperature difference/cooling load factor/solar cooling load factor) cooling load calculation method was first introduced in the 1979 ASHRAE Cooling and Heating Load Manual (GRP-158) [1] The CLTD/CLF/SCL Method is regarded as a reasonably accurate approximation of the total heat gains through a building envelope ...
ASHRAE was founded in 1894 at a meeting of engineers in New York City, formerly headquartered at 345 East 47th Street, and has held an annual meeting since 1895. [4] Until 1954 it was known as the American Society of Heating and Ventilating Engineers (ASHVE); in that year it changed its name to the American Society of Heating and Air-Conditioning Engineers (ASHAE). [5]
A module for Appendix G of ASHRAE 90.1-2010 is available, this is used for example in LEED and BREEAM. The integrated radiosity method with single reflection and one measuring point can be used for whole-year daylight analysis and allows modeling daylight-based control strategies (e.g. shading devices, artificial lightening).
The ASHRAE Handbook is the four-volume flagship publication of the nonprofit technical organization ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers [a]). This Handbook is considered the most comprehensive and authoritative repository of practical knowledge on the various topics that form the field of heating ...
Space By Space Method. A defined list of many possible space types within a building the associated watts per square foot allowance. For example, ANSI/ASHRAE/IESNA Standard 90.1-2007 allows the Emergency Space of a hospital to be designed for 2.7 watts per square foot, but the Recovery areas of a hospital would be allowed 0.8 watts per square foot.
For example, energy codes such as ASHRAE 90.1 and the IECC prescribe U-values. However, R-value is widely used in practice to describe the thermal resistance of insulation products, layers, and most other parts of the building enclosure (walls, floors, roofs).