enow.com Web Search

  1. Ads

    related to: check coaxial cable for continuity

Search results

  1. Results from the WOW.Com Content Network
  2. Time-domain reflectometer - Wikipedia

    en.wikipedia.org/wiki/Time-domain_reflectometer

    These traces were produced by a commercial TDR using a step waveform with a 25 ps risetime, a sampling head with a 35 ps risetime, and an 18-inch (0.46 m) SMA cable. [9] The far end of the SMA cable was left open or connected to different adapters. It takes about 3 ns for the pulse to travel down the cable, reflect, and reach the sampling head.

  3. Continuity test - Wikipedia

    en.wikipedia.org/wiki/Continuity_test

    In electronics, a continuity test is the checking of an electric circuit to see if current flows (that it is in fact a complete circuit). A continuity test is performed by placing a small voltage (wired in series with an LED or noise-producing component such as a piezoelectric speaker ) across the chosen path.

  4. Cable tester - Wikipedia

    en.wikipedia.org/wiki/Cable_tester

    A cable tester is an electronic device used to verify the electrical connections in a signal cable or other wired assembly. Basic cable testers are continuity testers that verify the existence of a conductive path between ends of the cable, and verify the correct wiring of connectors on the cable. More advanced cable testers can measure the ...

  5. Continuity tester - Wikipedia

    en.wikipedia.org/wiki/Continuity_tester

    Entry-level cable testers are essentially continuity testers. A continuity tester is an item of electrical test equipment used to determine if an electrical path can be established between two points; [1] that is if an electrical circuit can be made. The circuit under test is completely de-energized prior to connecting the apparatus. [1]

  6. VLF cable testing - Wikipedia

    en.wikipedia.org/wiki/VLF_cable_testing

    The VLF test can be used in a number of ways: Apply VLF to cables in a simple withstand approach to detect potential failures in the cable insulation during a planned outage. The tested cable must withstand an AC voltage for a specified testing time without flashover. This method yields a "pass/fail" statement.

  7. Reflections of signals on conducting lines - Wikipedia

    en.wikipedia.org/wiki/Reflections_of_signals_on...

    A time-domain reflectometer; an instrument used to locate the position of faults on lines from the time taken for a reflected wave to return from the discontinuity.. A signal travelling along an electrical transmission line will be partly, or wholly, reflected back in the opposite direction when the travelling signal encounters a discontinuity in the characteristic impedance of the line, or if ...

  1. Ads

    related to: check coaxial cable for continuity