  1. Ad

    related to: what temperature is a fire alarm working

Search results

  1. Results from the WOW.Com Content Network
  2. Heat detector - Wikipedia

    en.wikipedia.org/wiki/Heat_detector

    Rate-of-Rise (ROR) heat detectors operate on a rapid rise in element temperature of 6.7 to 8.3°C (12.1 to 14.9°F) increase per minute, irrespective of the starting temperature. This type of heat detector can operate at a lower temperature fire condition than would be possible if the threshold were fixed.

  3. Linear heat detection - Wikipedia

    en.wikipedia.org/wiki/Linear_Heat_Detection

    Linear heat detection (LHD) (also known as linear detection wire or linear heat detection cable or linear heat) is a very commonly used method of fire detection. It can detect a fire anywhere along the length of the cable, and can be of lengths in excess of a kilometer. Applications can range from building fire alarm systems to mobile plant ...

  4. Fire alarm system - Wikipedia

    en.wikipedia.org/wiki/Fire_alarm_system

    A fire alarm system is a building system designed to detect, alert occupants, and alert emergency forces of the presence of fire, smoke, ...

  5. Smoke detector - Wikipedia

    en.wikipedia.org/wiki/Smoke_detector

    Some smoke alarms use a combination of the 2; usually using the 9V battery as an extra power source in the event of an outage. Commercial smoke detectors issue a signal to a fire alarm control panel as part of a fire alarm system. Usually, an individual commercial smoke detector unit does not issue an alarm; some, however, have built-in sounders.

  6. Flame detector - Wikipedia

    en.wikipedia.org/wiki/Flame_detector

    A flame detector is a sensor designed to detect and respond to the presence of a flame or fire, allowing flame detection.Responses to a detected flame depend on the installation, but can include sounding an alarm, deactivating a fuel line (such as a propane or a natural gas line), and activating a fire suppression system.

  7. Fire sprinkler system - Wikipedia

    en.wikipedia.org/wiki/Fire_sprinkler_system

    In addition, a sprinkler will usually activate within one to four minutes of the fire's start, whereas it typically takes at least five minutes for a fire department to register an alarm and drive to the fire site, and an additional ten minutes to set up equipment and apply hose streams to the fire.

  8. Be safe with Thanksgiving cooking with these tips from ... - AOL

    www.aol.com/safe-thanksgiving-cooking-tips-mary...

    Test your smoke alarms to ensure they are working properly. Additionally, ensure your guests are aware of all available exits if a fire occurs and have them meet at a designated location outside.

  9. Fire damper - Wikipedia

    en.wikipedia.org/wiki/Fire_damper

    Fire/smoke dampers are similar to fire dampers in fire resistance rating, and also prevent the spread of smoke inside the ducts. When a rise in temperature occurs, the fire damper closes, usually activated by a thermal element which melts at temperatures higher than ambient but low enough to indicate the presence of a fire, allowing springs to ...