A Zigzag pattern of fetal heart rate (FHR) is defined as FHR baseline amplitude changes of more than 25 beats per minute (bpm) with a minimum duration of 2 minutes and maximum of 30 minutes. [19] However, according to another study, even a >1 min duration of the zigzag pattern is associated with an increased risk of adverse neonatal outcomes. [21]
A normal nonstress test will show a baseline fetal heart rate between 110 and 160 beats per minute with moderate variability (5- to 25-interbeat variability) and 2 qualifying accelerations in 20 minutes with no decelerations. "Reactive" is defined as the presence of two or more fetal heart rate accelerations within a 20-minute period. Each ...
During uterine contractions, fetal oxygenation is worsened. Late decelerations in fetal heart rate occurring during uterine contractions are associated with increased fetal death rate, growth retardation and neonatal depression. [1] [2] This test assesses fetal heart rate in response to uterine contractions via electronic fetal monitoring.
The presence of these biophysical variables implies absence of significant central nervous system hypoxemia/acidemia at the time of testing. By comparison, a compromised fetus typically exhibits loss of accelerations of the fetal heart rate (FHR), decreased body movement and breathing, hypotonia, and, less acutely, decreased amniotic fluid volume.
Amnioinfusion is a method in which isotonic fluid is instilled into the uterine cavity.. It was introduced in the 1960s as a means of terminating pregnancy and inducing labor in intrauterine death, but is currently used as a treatment in order to correct fetal heart rate changes caused by umbilical cord compression, indicated by variable decelerations seen on fetal heart rate monitoring.
The condition is detected most often with electronic fetal heart rate (FHR) monitoring through cardiotocography (CTG), which allows clinicians to measure changes in the fetal cardiac response to declining oxygen. [1] [5] [4] Specifically, heart rate decelerations detected on CTG can represent danger to the fetus and to delivery. [4]
A Doppler fetal monitor, informally known as sonicaid (generic trademark), is a hand-held ultrasound transducer used to detect the fetal heartbeat for prenatal care. It uses the Doppler effect to provide an audible simulation of the heart beat. Some models also display the heart rate in beats per minute (BPM).
The use of phonocardiography to study the fetal heart dates back to the 1960s, when researchers first began to explore the feasibility of detecting fetal heart sounds using external microphones. [10] Early studies focused on using phonocardiography to measure fetal heart rate and rhythm. Over time, advances in technology and techniques have ...