enow.com Web Search

  1. Ads

    related to: primary wire vs secondary

Search results

  1. Results from the WOW.Com Content Network
  2. Electric power distribution - Wikipedia

    en.wikipedia.org/wiki/Electric_power_distribution

    Closer to the customer, a distribution transformer steps the primary distribution power down to a low-voltage secondary circuit, usually 120/240 V in the US for residential customers. The power comes to the customer via a service drop and an electricity meter. The final circuit in an urban system may be less than 15 metres (50 ft) but may be ...

  3. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    A transformer supplying a three-wire distribution system has a single-phase input (primary) winding. The output (secondary) winding has a center tap connected to a grounded neutral. As shown in Fig. 1, either end to center has half the voltage of end-to-end. Fig. 2 illustrates the phasor diagram of the output voltages for a split-phase transformer.

  4. Distribution transformer - Wikipedia

    en.wikipedia.org/wiki/Distribution_transformer

    In Europe and other countries using its system, the secondary is often the three-phase 400Y/230 system. There are three 230 V secondary windings, each receiving power from a primary winding attached to one of the primary phases. One end of each secondary winding is connected to a 'neutral' wire, which is grounded.

  5. Utility pole - Wikipedia

    en.wikipedia.org/wiki/Utility_pole

    Typical North American utility pole, showing hardware for a residential 240/120 V split-phase service drop: (A,B,C) 3-phase primary distribution wires (mounted on a crossarm), (D) neutral wire, (E) fuse cutout, (F) lightning arrestor, (G) single-phase distribution transformer, (H) ground wire to transformer case, (J) "triplex" service drop ...

  6. High-leg delta - Wikipedia

    en.wikipedia.org/wiki/High-leg_delta

    High-leg delta service is supplied in one of two ways. One is by a three-phase transformer (or three single-phase transformers), having four wires coming out of the secondary, the three phases, plus a neutral connected as a center-tap on one of the windings. Another method (the open delta configuration) requires two transformers.

  7. Transformer types - Wikipedia

    en.wikipedia.org/wiki/Transformer_types

    The primary may be connected phase to ground or phase to phase. The secondary is usually grounded on one terminal. There are three primary types of voltage transformers (VT): electromagnetic, capacitor, and optical. The electromagnetic voltage transformer is a wire-wound transformer.

  1. Ads

    related to: primary wire vs secondary