The CIE 1924 photopic V(λ) luminosity function, [cie 3] which is included in the CIE 1931 color-matching functions as the y (λ) function, has long been acknowledged to underestimate the contribution of the blue end of the spectrum to perceived luminance. There have been numerous attempts to improve the standard function, to make it more ...
Photopic vision is the vision of the eye under well-lit conditions (luminance levels from 10 to 10 8 cd/m 2). In humans and many other animals, photopic vision allows color perception , mediated by cone cells , and a significantly higher visual acuity and temporal resolution than available with scotopic vision .
A comparison between a typical normalized M cone's spectral sensitivity and the CIE 1931 luminosity function for a standard observer in photopic vision. In the CIE 1931 model, Y is the luminance, Z is quasi-equal to blue (of CIE RGB), and X is a mix of the three CIE RGB curves chosen to be nonnegative (see § Definition of the CIE XYZ color space).
In modern photometry, the radiant power at each wavelength is weighted by a luminosity function that models human brightness sensitivity. Typically, this weighting function is the photopic sensitivity function, although the scotopic function or other functions may also be applied in the same way. The weightings are standardized by the CIE and ...
For low light levels, the response of the human eye changes, and the scotopic curve applies. The photopic curve is the CIE standard curve used in the CIE 1931 color space. The luminous flux (or visible power) in a light source is defined by the photopic luminosity function. The following equation calculates the total luminous flux in a source ...
However, the overall luminosity function (which in fact is a weighted sum of these three curves) is subjective, since it involves asking a test person whether two light sources have the same brightness, even if they are in completely different colors. Along the same lines, the relative magnitudes of the X, Y, and Z curves are arbitrarily chosen ...
Date/Time Thumbnail Dimensions User Comment; current: 23:55, 17 March 2013: 446 × 271 (21 KB): Fuzzypeg {{subst:Upload marker added by en.wp UW}} {{Information |Description = {{en|Comparison between CIE 1931 photopic luminosity function and a typical normalized M cone response.
For example, if the spectral distributions are constrained to be the result of mixing three monochromatic sources, (as was done in the measurement of the CIE 1931 and the Stiles and Burch [1] color matching functions), then there will be a one-to-one relationship between the LMS and CIE 1931 XYZ coordinates of a particular color.