Search results
Results from the WOW.Com Content Network
Titration (also known as titrimetry [1] and volumetric analysis) is a common laboratory method of quantitative chemical analysis to determine the concentration of an identified analyte (a substance to be analyzed). A reagent, termed the titrant or titrator, [2] is prepared as a standard solution of known concentration and volume.
Differences in the temperature between the titrant and the titrand; Evaporative losses from the surface of the rapidly mixed fluid; Heats of solution when the titrant solvent is mixed with the analyte solvent; Heat introduced by the mechanical action of stirring (minor influence); and; Heat produced by the thermistor itself (very minor influence).
The ratio of peak areas between the internal standard and analyte is calculated to determine analyte concentration. [12] A common type of internal standard is an isotopically labeled analogue of the analyte, which incorporates one or more atoms of 2 H, 13 C, 15 N and 18 O into its structure. [13]
Analytical chemistry studies and uses instruments and methods to separate, identify, and quantify matter. [1] In practice, separation, identification or quantification may constitute the entire analysis or be combined with another method. Separation isolates analytes.
An analyte, component (in clinical chemistry), titrand (in titrations), or chemical species is a substance or chemical constituent that is of interest in an analytical procedure. The remainder of the sample is called the matrix. The procedure of analysis measures the analyte's chemical or physical properties, thus establishing its identity or ...
Although KF is a destructive analysis, the sample quantity is small and is typically limited by the accuracy of weighing. For example, in order to obtain an accuracy of 1% using a scale with the typical accuracy of 0.2 mg, the sample must contain 20 mg water, which is e.g. 200 mg for a sample with 10% water.
A Gran plot (also known as Gran titration or the Gran method) is a common means of standardizing a titrate or titrant by estimating the equivalence volume or end point in a strong acid-strong base titration or in a potentiometric titration.
When the analyte is completely consumed, endpoint detection is employed, preferably with an instrumental method for higher precision. [6] The total charge that has flowed through the sample can be determined from the magnitude of the current (in amperes ) and the duration of the current (in seconds).