Crista supraventricularis is a muscular ridge within the right ventricle of the heart. It is located between the tricuspid and pulmonic valves, at the junction of the right ventricular anterior (free) wall and the interventricular septum. It has a "U-shaped" morphology, which serves as a "trough" for the proximal right coronary artery. [1]
Right atrial enlargement (RAE) is clinically significant due to its prevalence in diagnosing supraventricular arrhythmias. Further, early diagnosis using risk factors like RAE may decrease mortality because patients with RAE are at 9x more risk of arrhythmias and other cardiac conditions compared to their healthy counterparts. [ 2 ]
Bachmann's bundle receives its blood supply from the sinoatrial nodal artery (right, left or both). [4]Besides Bachmann's bundle, the other three conduction tracts that constitute the atrial conduction system are known as the anterior, middle, and posterior tracts, which run from the sinoatrial node to the atrioventricular node, converging in the region near the coronary sinus.
The right atrial appendage (lat: auricula atrii dextra) is located at the front upper surface of the right atrium. Looking from the front, the right atrial appendage appears wedge-shaped or triangular. Its base surrounds the superior vena cava. [6] The right atrial appendage is a pouch-like extension of the right atrium and is covered by a ...
The Bainbridge reflex (or Bainbridge effect or atrial reflex) is a cardiovascular reflex causing an increase in heart rate in response to increased stretching of the wall of the right atrium and/or the inferior vena cava as a result of increased venous filling (i.e., increased preload).
Electron micrograph of ventricular (left) and atrial myocyte (right) showing location of ANP storage granules in a mouse model. Captured by Dr. Stephen C. Pang from Queen's University . Atrial natriuretic peptide ( ANP ) or atrial natriuretic factor ( ANF ) is a natriuretic peptide hormone secreted from the cardiac atria that in humans is ...
Tricuspid regurgitation (TR), also called tricuspid insufficiency, is a type of valvular heart disease in which the tricuspid valve of the heart, located between the right atrium and right ventricle, does not close completely when the right ventricle contracts ().
Cardiac resynchronisation therapy (CRT or CRT-P) is the insertion of electrodes in the left and right ventricles of the heart, as well as on occasion the right atrium, to treat heart failure by coordinating the function of the left and right ventricles via a pacemaker, a small device inserted into the anterior chest wall.