Level 2 contains the SCADA to readings and equipment status reports that are communicated to level 2 SCADA as required. Data is then compiled and formatted in such a way that a control room operator using the human-machine interface (HMI) can make supervisory decisions to adjust or override normal RTU (PLC) controls.
A remote terminal unit (RTU) is a microprocessor-controlled electronic device that interfaces objects in the physical world to a distributed control system or SCADA (supervisory control and data acquisition) system by transmitting telemetry data to a master system, and by using messages from the master supervisory system to control connected objects. [1]
The Remote Terminal Unit is initially interrogated with what DNP3 terms an "Integrity Poll" (a combined Read of Class 1, 2, 3 and 0 data). This causes the Remote Terminal Unit to send all buffered events and also all static point data to the Master station. Following this, the Master polls for the event data by reading Class 1, Class 2 or Class 3.
An energy management system (EMS) is a system of computer-aided tools used by operators of electric utility grids to monitor, control, and optimize the performance of the generation or transmission system. Also, it can be used in small scale systems like microgrids. [1] [2]
The Inter-Control Center Communications Protocol (ICCP or IEC 60870-6/TASE.2) [3] is being specified by utility organizations throughout the world to provide data exchange over wide area networks (WANs) between utility control centers, utilities, power pools, regional control centers, and Non-Utility Generators.
HVAC (Heating, Ventilation and Air Conditioning) equipment needs a control system to regulate the operation of a heating and/or air conditioning system. [1] Usually a sensing device is used to compare the actual state (e.g. temperature) with a target state. Then the control system draws a conclusion what action has to be taken (e.g. start the ...
Most IEDs have a communication port and built-in support for standard communication protocols (DNP3, IEC104 or IEC61850), so they can communicate directly with the SCADA system or a substation programmable logic controller. Alternatively, they can be connected to a substation RTU that acts as a gateway towards the SCADA server.
SIMATIC WinCC is a supervisory control and data acquisition (SCADA) and human-machine interface (HMI) system from Siemens. SCADA systems are used to monitor and control physical processes involved in industry and infrastructure on a large scale and over long distances. SIMATIC WinCC can be used in combination with Siemens controllers.