Search results
Results from the WOW.Com Content Network
The central peak is at the ZPD position ("zero path difference" or zero retardation), where the maximal amount of light passes through the interferometer to the detector. The goal of absorption spectroscopy techniques (FTIR, ultraviolet-visible ("UV-vis") spectroscopy , etc.) is to measure how much light a sample absorbs at each wavelength. [ 2 ]
multiple broad peaks C─O alcohols: primary 1040–1060 strong, broad secondary ~1100 strong tertiary 1150–1200 medium phenols any 1200 ethers aliphatic 1120 aromatic 1220–1260 carboxylic acids any 1250–1300 esters any 1100–1300 two bands (distinct from ketones, which do not possess a C─O bond) C─N aliphatic amines any 1020–1220
Transmission mode is the most widely used FTIR technique in geoscience due to its high analysis speed and cost-efficient characteristics. [ 4 ] The sample, either a rock or a mineral, is cut into a block and polished on both sides until a thin (typically 300 to 15 μm) wafer is created.
The dispersive method is more common in UV-Vis spectroscopy, but is less practical in the infrared than the FTIR method. One reason that FTIR is favored is called "Fellgett's advantage" or the "multiplex advantage": The information at all frequencies is collected simultaneously, improving both speed and signal-to-noise ratio.
The schematic representation of a nano-FTIR system with a broadband infrared source. Nano-FTIR (nanoscale Fourier transform infrared spectroscopy) is a scanning probe technique that utilizes as a combination of two techniques: Fourier transform infrared spectroscopy (FTIR) and scattering-type scanning near-field optical microscopy (s-SNOM).
MS-alone and multiMS-toolbox is a tool chain for mass spectrometry data peak extraction and statistical analysis. mzCloud Website: Web-based mass spectral database that comprises a collection of high and low resolution tandem mass spectrometry data acquired under a number of experimental conditions. MZmine Open source
A common spectroscopic method for analysis is Fourier transform infrared spectroscopy (FTIR), where chemical bonds can be detected through their characteristic infrared absorption frequencies or wavelengths. These absorption characteristics make infrared analyzers an invaluable tool in geoscience, environmental science, and atmospheric science.
PeakFit is an automated nonlinear peak separation and analysis software package for scientists performing spectroscopy, chromatography and electrophoresis.. PeakFit automatically finds and fits up to 100 peaks to a data set, at a time, enabling users to characterize peaks and find the best equation that fits their data.