  2. List of instruments used in microbiological sterilization and ...

    en.wikipedia.org/wiki/List_of_instruments_used...

    Koch's or Arnold's steam sterilizer: used for steam sterilization A pressure cooker: used as a portable autoclave Biological and chemical indicators: Used to ascertain if a certain process has been completed, e.g. spores used in an autoclave are killed if autoclaving is properly done Filters: •Candle filter:

  3. Infection prevention and control - Wikipedia

    en.wikipedia.org/wiki/Infection_prevention_and...

    Sterilization using steam can also be done at a temperature of 132 C (270 F), at a double pressure. [citation needed] Dry heat sterilization is performed at 170 C (340 F) for one hour or two hours at a temperature of 160 C (320 F). Dry heat sterilization can also be performed at 121 C, for at least 16 hours. [17]

  4. Autoclave - Wikipedia

    en.wikipedia.org/wiki/Autoclave

    An autoclave is a machine used to carry out industrial and scientific processes requiring elevated temperature and pressure in relation to ambient pressure and/or temperature. Autoclaves are used before surgical procedures to perform sterilization and in the chemical industry to cure coatings and vulcanize rubber and for hydrothermal synthesis ...

  5. Sterilization (microbiology) - Wikipedia

    en.wikipedia.org/wiki/Sterilization_(microbiology)

    Proper autoclave treatment will inactivate all resistant bacterial spores in addition to fungi, bacteria, and viruses, but is not expected to eliminate all prions, which vary in their heat resistance. For prion elimination, various recommendations state 121–132 °C (250–270 °F) for 60 minutes or 134 °C (273 °F) for at least 18 minutes. [14]

  6. Central sterile services department - Wikipedia

    en.wikipedia.org/wiki/Central_sterile_services...

    Sterile dental instruments from hospital central supply (barcoded label indicating sterilization date, expiry date and contents). The central sterile services department (CSSD), also called sterile processing department (SPD), sterile processing, central supply department (CSD), or central supply, is an integrated place in hospitals and other health care facilities that performs sterilization ...

  7. Advisory Committee on Immunization Practices - Wikipedia

    en.wikipedia.org/wiki/Advisory_Committee_on...

    ACIP statements are official federal recommendations for the use of vaccines and immune globulins in the U.S., and are published by the CDC. ACIP reports directly to the CDC director, although its management and support services are provided by CDC's National Center for Immunization and Respiratory Diseases. [1]

  8. Biosafety level - Wikipedia

    en.wikipedia.org/wiki/Biosafety_level

    CDC technician dons an older-model positive-pressure suit before entering one of the CDC's earlier BSL-4 labs. Biosafety level 4 (BSL-4) is the highest level of biosafety precautions, and is appropriate for work with agents that could easily be aerosol-transmitted within the laboratory and cause severe to fatal disease in humans for which there ...

  9. Sterility assurance level - Wikipedia

    en.wikipedia.org/wiki/Sterility_assurance_level

    For example, medical device manufacturers design their sterilization processes for an extremely low SAL, such as 10 −6, which is a 1 in 1,000,000 chance of a non-sterile unit. SAL also describes the killing efficacy of a sterilization process. A very effective sterilization process has a very low SAL.