Search results

  1. Results from the WOW.Com Content Network
  2. Blower door - Wikipedia

    en.wikipedia.org/wiki/Blower_door

    A duct test can be combined with a blower door test to measure the total leakage to outside, measuring effective leakage to the outside of the house only. Finding air leaks in a building using an infrared camera while the house is depressurized. A blower door is not mandatory for an infrared reading, but the drawing in of outside air ...

  3. Duct leakage testing - Wikipedia

    en.wikipedia.org/wiki/Duct_leakage_testing

    Duct leakage test in the US. A duct leakage tester is a diagnostic tool designed to measure the airtightness of forced air heating, ventilating and air-conditioning (HVAC) ductwork. A duct leakage tester consists of a calibrated fan for measuring an air flow rate and a pressure sensing device to measure the pressure created by the fan flow.

  4. Ductwork airtightness - Wikipedia

    en.wikipedia.org/wiki/Ductwork_airtightness

    The relationship between pressure and leakage air flow rate is defined by the power law model between the airflow rate and the pressure difference across the ductwork envelope as follows: q L =C L ∆p n. where: q L is the volumetric leakage airflow rate expressed in L.s −1; C L is the air leakage coefficient expressed in L.s −1.Pa −n

  5. Building airtightness - Wikipedia

    en.wikipedia.org/wiki/Building_airtightness

    The relationship between pressure and leakage air flow rate is defined by the power law between the airflow rate and the pressure difference across the building envelope as follows: [16] q L =C L ∆p n. where: q L is the volumetric leakage airflow rate expressed in m 3 h −1; C L is the air leakage coefficient expressed in m 3 h −1 Pa −n

  6. Mechanical systems drawing - Wikipedia

    en.wikipedia.org/wiki/Mechanical_systems_drawing

    A drawing the intended locations of plant items and service routes in such detail as to indicate the design intent. The main features of detailed design drawings should be as follows: Plan layouts to a scale of at least 1:100. Plant areas to a scale of at least 1:50 and accompanied by cross-sections.

  7. Infiltration (HVAC) - Wikipedia

    en.wikipedia.org/wiki/Infiltration_(HVAC)

    Infiltration is sometimes called air leakage. The leakage of room air out of a building, intentionally or not, is called exfiltration . Infiltration is caused by wind , negative pressurization of the building, and by air buoyancy forces known commonly as the stack effect .

  8. Remove Banner Ads with Ad-Free AOL Mail | AOL Products

    www.aol.com/products/utilities/ad-free-mail

    AOL Promotions. You’ll no longer see paid ads, but you’ll continue to see promotions for AOL products and brands. We want to keep you in-the-know of our latest product news and information.

  9. Stack effect - Wikipedia

    en.wikipedia.org/wiki/Stack_effect

    In a modern high-rise building with a well-sealed envelope, the stack effect can create significant pressure differences that must be given design consideration and may need to be addressed with mechanical ventilation. Stairwells, shafts, elevators, and the like, tend to contribute to the stack effect, while interior partitions, floors, and ...