Figure 1. The light path through a Michelson interferometer.The two light rays with a common source combine at the half-silvered mirror to reach the detector. They may either interfere constructively (strengthening in intensity) if their light waves arrive in phase, or interfere destructively (weakening in intensity) if they arrive out of phase, depending on the exact distances between the ...
Figure 2. File:Twyman-Green interferometer set up as a white light scanner. Vertical scanning interferometry is an example of low-coherence interferometry, which exploits the low coherence of white light. Interference will only be achieved when the path length delays of the interferometer are matched within the coherence time of the light source.
A Common path interferometer has the test and reference beams traveling over effectively the same path which has the advantage that you can use an inexpensive semiconducting laser pointer with low coherence versus other interferometers which need a high coherence laser (typically a He Ne laser).
The Lummer–Gehrcke interferometer or Lummer–Gehrcke plate is a multiple-beam interferometer similar to the Fabry–Pérot etalon, but using light at a steep angle of incidence. The interferometer consists of a long plate of glass or quartz , with faces that are polished accurately flat and parallel. [ 1 ]
Schematic diagram of a Michelson interferometer, configured for FTIR. In a Michelson interferometer adapted for FTIR, light from the polychromatic infrared source, approximately a black-body radiator, is collimated and directed to a beam splitter. Ideally 50% of the light is refracted towards the fixed mirror and 50% is transmitted towards the ...
The Michelson interferometer (among other interferometer configurations) is employed in many scientific experiments and became well known for its use by Michelson and Edward Morley in the famous Michelson–Morley experiment (1887) [1] in a configuration which would have detected the Earth's motion through the supposed luminiferous aether that ...
The Twyman–Green interferometer, a double path interferometer, is a variant of the Michelson interferometer that is commonly used to test the precision of optical surfaces and lenses. [ 30 ] [ 31 ] Since reference and sample paths are divergent, this form of interferometer is extremely sensitive to vibration and to atmospheric turbulence in ...
If a phase-shifting element is added to one arm of the interferometer, then the displacement it causes can be determined by simply counting the interference fringes, i.e., the minima. The Jamin interferometer allows very exact measurements of the refractive index and dispersion of gases ; a transparent pressure chamber can be positioned in the ...