The dead load includes loads that are relatively constant over time, including the weight of the structure itself, and immovable fixtures such as walls, plasterboard or carpet. The roof is also a dead load. Dead loads are also known as permanent or static loads. Building materials are not dead loads until constructed in permanent position.
In essence all these loads are dynamic, including the self-weight of the structure because at some point in time these loads were not there. The distinction is made between the dynamic and the static analysis on the basis of whether the applied action has enough acceleration in comparison to the structure's natural frequency.
Kentledge load testing in Haikou, Hainan, China. Static load testing is an in situ type of load testing used in geotechnical investigation to determine the bearing capacity of deep foundations prior to the construction of a building. It differs from the statnamic load test and dynamic load testing in that the pressure applied to the pile is slower.
In the context to structural analysis, a structure refers to a body or system of connected parts used to support a load. Important examples related to Civil Engineering include buildings, bridges, and towers; and in other branches of engineering, ship and aircraft frames, tanks, pressure vessels, mechanical systems, and electrical supporting structures are important.
Structural engineering depends on the knowledge of materials and their properties, in order to understand how different materials support and resist loads. It also involves a knowledge of Corrosion engineering to avoid for example galvanic coupling of dissimilar materials. Common structural materials are: Iron: wrought iron, cast iron
This page was last edited on 12 January 2021, at 07:18 (UTC).; Text is available under the Creative Commons Attribution-ShareAlike 4.0 License; additional terms may apply.
For example, in the case of design for fire a load case of 1.0 x Dead Load + 0.8 x Live Load may be used, as it is reasonable to assume everyone has left the building if there is a fire. In multi-story buildings it is normal to reduce the total live load depending on the number of stories being supported, as the probability of maximum load ...
The macrostructures considered here may be composed of "structural elements" which material presents a "microstructure". Whether searching to limit the stress or the deformation, macrostructure, structural element and microstructure have each, a weight Vρ, when ρ is the volumic weight of materials, in N/m 3, function of the solicitations {F 0} (for "force" in général) applied to them, of ...