However, in the lighting industry it is often associated with the lighting power allowance (LPA) permitted by the building energy code in question. The Oregon Department of Energy defines lighting power density as "The maximum allowable lighting density permitted by the code. It is expressed in watts per square foot for a given occupancy/space ...
Radiant intensity, a radiometric quantity measured in watts per steradian (W/sr) Luminous intensity, a photometric quantity measured in lumens per steradian (lm/sr), or candela (cd) Irradiance, a radiometric quantity, measured in watts per square meter (W/m 2) Intensity (physics), the name for irradiance used in other branches of physics (W/m 2)
Solar irradiance is the power per unit area (surface power density) received from the Sun in the form of electromagnetic radiation in the wavelength range of the measuring instrument. Solar irradiance is measured in watts per square metre (W/m 2 ) in SI units .
Mathematically, for the spectral power distribution of a radiant exitance or irradiance one may write: =where M(λ) is the spectral irradiance (or exitance) of the light (SI units: W/m 2 = kg·m −1 ·s −3); Φ is the radiant flux of the source (SI unit: watt, W); A is the area over which the radiant flux is integrated (SI unit: square meter, m 2); and λ is the wavelength (SI unit: meter, m).
A foot-candle (sometimes foot candle; abbreviated fc, lm/ft 2, or sometimes ft-c) is a non-SI unit of illuminance or light intensity. The foot-candle is defined as one lumen per square foot. This unit is commonly used in lighting layouts in parts of the world where United States customary units are used, mainly the United States. [ 1 ]
As the source emits electromagnetic radiation of a given wavelength, the far-field electric component of the wave E, the far-field magnetic component H, and power density are related by the equations: E = H × 377 and Pd = E × H. Pd = H 2 × 377 and Pd = E 2 ÷ 377 where Pd is the power density in watts per square meter (one W/m 2 is equal to ...
ANSI/ASHRAE/IES Standard 90.1: Energy Standard for Buildings Except Low-Rise Residential Buildings is an American National Standards Institute (ANSI) standard published by ASHRAE and jointly sponsored by the Illuminating Engineering Society (IES) that provides minimum requirements for energy efficient designs for buildings except for low-rise residential buildings (i.e. single-family homes ...
² Buildings which comply with [GR-1] and [GR-3] may also fulfill minimum requirements for Section 179D Federal Energy Tax Deduction and may qualify for a $0.30 - $0.60 per square foot tax incentive. ³ Buildings which comply with [GR-4] may also fulfill LEED Energy & Atmosphere (EA) Prerequisite 1: Fundamental Commissioning of Building Energy ...