Steel studs are gaining popularity as a non-combustible alternative, especially for non load-bearing walls, and are required in some firewalls. In New Zealand, the required lumber size and spacing of wall studs are determined using NZS 3604 Timber-framed buildings table 8.2 for loadbearing walls and table 8.4 for non-loadbearing walls. [4]
Interior loadbearing walls are framed in the same way as exterior walls. Studs are usually 1 + 1 ⁄ 2 in × 3 + 1 ⁄ 2 in (38 mm × 89 mm) lumber spaced at 16 in (410 mm) on center. This spacing may be changed to 12 or 24 in (300 or 610 mm) depending on the loads supported and the type and thickness of the wall finish used. [12]
Wood furring strips typically measure 1 x 2 or 1 x 3 inches. They can be laid out perpendicular to studs or joists and nailed to them, or set vertically against an existing wall surface. The spacing between the strips depends on the type of finishing material. Wider spacing is typically used behind the heavy boards that support ceramic tiles.
Various sized cuts of 1 ⁄ 2 in (13 mm) drywall with tools for maintenance and installation . Drywall (also called plasterboard, dry lining, [1] wallboard, sheet rock, gib board, gypsum board, buster board, turtles board, slap board, custard board, gypsum panel and gyprock) is a panel made of calcium sulfate dihydrate (), with or without additives, typically extruded between thick sheets of ...
Generally, wool batts have thicknesses of 50 mm (2 in) to 100mm (4 in), with widths of 400 mm (16 in) and 600 mm (24 in), and lengths of 4000 mm (13 ft 4 in), 5000 mm (16 ft 8 in), 6000 mm (20 ft) and 7200 mm (24 ft). The widths of 16 in and 24 in are the standard measurements between studs in a stud frame wall.
These are narrow strips of wood, extruded metal, or split boards, nailed horizontally across the wall studs or ceiling joists. Each wall frame is covered in lath, tacked at the studs. Wood lath is typically about one inch (2.5 cm) wide by four feet (1.2 m) long by 1 ⁄ 4 inch (6 mm) thick. Each horizontal course of lath is spaced about 3 ⁄ 8 ...
The vertical studs are arranged in the tracks, usually spaced 16 inches (410 mm) apart, and fastened at the top and bottom. The typical profiles used in residential construction are the C-shape stud and the U-shaped track, and a variety of other profiles. Framing members are generally produced in a thickness of 12 to 25 gauge. Heavy gauges ...
In construction, a dwang (Scotland and New Zealand), [1] [2] [3] nogging piece, nogging, noggin or nog (England and Australia; all derived from brick nog), [4] [5] or blocking (North America), is a horizontal bracing piece used between wall studs to give rigidity to the wall frames of a building. Noggings may be made of timber, steel, or aluminium.