Search results
Results from the WOW.Com Content Network
In 1994, the US National Institute of Standards and Technology (NIST) defined "gasoline gallon equivalent (GGE) [as] 5.660 pounds of natural gas." [1] Compressed natural gas (CNG), for example, is a gas rather than a liquid. It can be measured by its volume in standard cubic feet (ft 3) at atmospheric conditions, by its weight in pounds (lb ...
The density of propane gas at 25 °C (77 °F) is 1.808 kg/m 3, about 1.5× the density of air at the same temperature. The density of liquid propane at 25 °C (77 °F) is 0.493 g/cm 3, which is equivalent to 4.11 pounds per U.S. liquid gallon or 493 g/L. Propane expands at 1.5% per 10 °F. Thus, liquid propane has a density of approximately 4.2 ...
The table below lists units supported by {{convert}}. More complete lists are linked for each dimension. For a complete list of all dimensions, see full list of units. {{Convert}} uses unit-codes, which are similar to, but not necessarily exactly the same as, the usual written abbreviation for a given unit. These unit-codes are displayed in ...
AMFA specifies the energy content of 100 cubic feet of natural gas to be equal to 0.823 gallons-equivalent of natural gas, and the gallon equivalency of natural gas is considered to have a fuel content, similar to that for alcohol fuels, equal to 0.15 gallons of fuel.
The heating value depends on the source of gas that is used and the process that is used to liquefy the gas. The range of heating value can span ±10 to 15 percent. A typical value of the higher heating value of LNG is approximately 50 MJ/kg or 21,500 BTU/lb. [2] A typical value of the lower heating value of LNG is 45 MJ/kg or 19,350 BTU/lb.
The Wobbe index is expressed in MJ/Nm³ (where 'Nm³' indicates'm³ in Normal conditions), or sometimes in BTU/scf.In the case of natural gas (molar mass 17 g/mol), the typical heating value is around 39 MJ/Nm³ (1,050 BTU/scf) and the specific gravity is approximately 0.59, giving a typical Wobbe index of 51 MJ/Nm³ (1,367 BTU/scf).
Yet other definitions are in use for industrial gas, [5] where, in the US, a standard cubic foot for industrial gas use is defined at 70 °F (21.1 °C) and 14.696 psia (101.325 kPa), while in Canada, a standard cubic meter for industrial gas use is defined at 15 °C (59 °F) and 101.325 kPa (14.696 psia).
The National Propane Gas Association has a generic MSDS available online here. (Issued 1996) MSDS from Suburban Propane, L.P dated 5/2013 in the SDSdata.org database