Counts per minute (abbreviated to cpm) is a measure of the detection rate of ionization events per minute. Counts are only manifested in the reading of the measuring instrument, and are not an absolute measure of the strength of the source of radiation. Whilst an instrument will display a rate of cpm, it does not have to detect counts for one ...
The concentration instantly steps up to its constant value when the time reaches 30 minutes, and there is a 100 count per minute (cpm) constant background. Note: A microcurie (Ci) is a measure of the disintegration rate, or activity, of a radioactive source; it is 2.22E06 disintegrations per minute.
1 Bq = 1 s −1. A special name was introduced for the reciprocal second (s −1) to represent radioactivity to avoid potentially dangerous mistakes with prefixes.For example, 1 μs −1 would mean 10 6 disintegrations per second: (10 −6 s) −1 = 10 6 s −1, [4] whereas 1 μBq would mean 1 disintegration per 1 million seconds.
There are two types of detected radiation readout: counts and radiation dose. The counts display is the simplest, and shows the number of ionizing events detected, displayed either as a count rate, such as "counts per minute" or "counts per second", or as a total number of counts over a set time period (an integrated total). The counts readout ...
The rep has variously been defined as 83 or 93 ergs per gram of tissue (8.3/9.3 mGy) [13] or per cc of tissue. [14] In 1953 the ICRU recommended the rad, equal to 100 erg/g as a new unit of absorbed radiation, [15] but then promoted a switch to the gray in the 1970s.
The roentgen or röntgen (/ ˈ r ɛ n t ɡ ə n,-dʒ ə n, ˈ r ʌ n t-/; [2] symbol R) is a legacy unit of measurement for the exposure of X-rays and gamma rays, and is defined as the electric charge freed by such radiation in a specified volume of air divided by the mass of that air (statcoulomb per kilogram).
The choice of this tube is intended to strike a balance between sensitivity and ruggedness and detects gamma radiation at energy levels of between 20 and 1000 Kev. The analogue dial is calibrated in both milliroentgens per hour and Counts Per Minute (CPM).
Stochastic effects are those that occur randomly, such as radiation-induced cancer. The consensus of the nuclear industry, nuclear regulators, and governments, is that the incidence of cancers caused by ionizing radiation can be modeled as increasing linearly with effective dose at a rate of 0.055% per rem (5.5%/Sv). [10]