Search results

  1. Results from the WOW.Com Content Network
  2. Cardiac resynchronization therapy - Wikipedia

    en.wikipedia.org/wiki/Cardiac_resynchronization...

    Cardiac resynchronisation therapy (CRT or CRT-P) is the insertion of electrodes in the left and right ventricles of the heart, as well as on occasion the right atrium, to treat heart failure by coordinating the function of the left and right ventricles via a pacemaker, a small device inserted into the anterior chest wall.

  3. Cardiac contractility modulation - Wikipedia

    en.wikipedia.org/wiki/Cardiac_contractility...

    The FDA approved the OPTIMIZER Smart System, which delivers cardiac contractility modulation therapy, as indicated to improve 6-minute hall walk distance, quality of life, and functional status of NYHA Class III heart failure patients who remain symptomatic despite guideline directed medical therapy, who are in normal sinus rhythm, are not indicated for cardiac resynchronization therapy, and ...

  4. Pacemaker - Wikipedia

    en.wikipedia.org/wiki/Pacemaker

    CRT devices have been shown to reduce mortality and improve quality of life in patients with heart failure symptoms; a LV ejection fraction less than or equal to 35% and QRS duration on EKG of 120 ms or greater. [18] [19] Biventricular pacing alone is referred to as CRT-P (for pacing).

  5. Pacemaker crosstalk - Wikipedia

    en.wikipedia.org/wiki/Pacemaker_crosstalk

    Crosstalk can only occur in a dual chamber or biventricular pacemaker. It happens less often in more recent models of dual chamber pacemakers due to the addition of a ventricular blanking period, which coincides with the atrial stimulus. This helps to prevent ventricular channel oversensing of atrial output.

  6. Third-degree atrioventricular block - Wikipedia

    en.wikipedia.org/wiki/Third-degree_atrio...

    Since pacemaker correction of the third-degree block requires full-time pacing of the ventricles, a potential side effect is pacemaker syndrome, and may necessitate the use of a biventricular pacemaker, which has an additional 3rd lead placed in a vein in the left ventricle, providing more coordinated pacing of both ventricles. [citation needed]

  7. Implantable cardioverter-defibrillator - Wikipedia

    en.wikipedia.org/wiki/Implantable_cardioverter...

    Illustration of Implantable Cardioverter Defibrillator (ICD) An implantable cardioverter-defibrillator (ICD) or automated implantable cardioverter defibrillator (AICD) is a device implantable inside the body, able to perform defibrillation, and depending on the type, cardioversion and pacing of the heart.

  8. Cardiomegaly - Wikipedia

    en.wikipedia.org/wiki/Cardiomegaly

    Pacemaker: Coordinates contractions between ventricles. In people at risk of arrhythmias, drug therapy or an implantable cardioverter-defibrillator (ICD). ICDs: Small devices implanted in the chest to monitor heart rhythm and deliver electrical shocks to control abnormal heartbeats.

  9. Coronary sinus - Wikipedia

    en.wikipedia.org/wiki/Coronary_sinus

    In Cardiac Resynchronization Therapy (CRT) procedures, a critical step involves the insertion of a pacing lead into the coronary vein system. However, the anatomical configuration of the coronary sinus (CS) exhibits significant variability, necessitating that cardiologists assess and evaluate its characteristics during the procedure.