The first method is the least accurate, according to ANSI/ASHRAE Standard 55, and the accuracy increases in order of the methods. [1] First, one can estimate the clothing insulation from the table provided in section five. If the clothing ensemble in question reasonably matches the clothing ensemble in the table, the indicated value can be used.
Although the concept of U-value (or U-factor) is universal, U-values can be expressed in different units. In most countries, U-value is expressed in SI units, as watts per square metre-kelvin: W/(m 2 ⋅K) In the United States, U-value is expressed as British thermal units (Btu) per hour-square feet-degrees Fahrenheit: Btu/(h⋅ft 2 ⋅°F)
It is acceptable to add or subtract garments on Table 2 from the ensembles in Table 1 to estimate the insulation of ensembles that differ in garment composition; It is possible to define a complete clothing ensemble as a combination of individual garments using Table 2. [1] Another unit that is used is the "tog": 1 tog = 0.1 K·m 2 ·W −1 ≈ ...
ASHRAE 55 provides a table of metabolic rates for a variety of activities. Some common values are 0.7 met for sleeping, 1.0 met for a seated and quiet position, 1.2–1.4 met for light activities standing, 2.0 met or more for activities that involve movement, walking, lifting heavy loads or operating machinery.
The U-value is used to refer to the amount of heat that can pass through a window, called thermal transmittance, with a lower score being better. [1] The U-factor of a window can often be found on the rating label of the window. Although the concept of U-value (or U-factor) is universal, U-values can be expressed in different units.
Members of ASHRAE receive the current volume, in both print and CD-ROM form, each year as a basic membership benefit. An enhanced electronic version, known as ASHRAE Handbook Online is a web-based version updated annually that contains the four latest volumes as well as extra content such as calculations, demonstration videos, and spreadsheets ...
Research completed in 1984 revealed some factors which were not accounted for in the original publication of the method; these findings were a result of the ASHRAE research project 359. In 1988 ASHRAE Research Project 472 worked to correct these oversights with the introduction of a classification system for walls, roofs, and zones ...
Air changes per hour is a measurement intended to communicate the air change effectiveness of a space’s ventilation system. Discussion around the ASHRAE standard 62, Ventilation for Acceptable Indoor Air Quality led to the development of a more direct method of measuring air change effectiveness with the use of a tracer gas. [1]