  2. Standing wave ratio - Wikipedia

    en.wikipedia.org/wiki/Standing_wave_ratio

    Voltage standing wave ratio (VSWR) (pronounced "vizwar" [1] [2]) is the ratio of maximum to minimum voltage on a transmission line . For example, a VSWR of 1.2 means a peak voltage 1.2 times the minimum voltage along that line, if the line is at least one half wavelength long.

  3. Scattering parameters - Wikipedia

    en.wikipedia.org/wiki/Scattering_parameters

    The voltage standing wave ratio (VSWR) at a port, represented by the lower case 's', is a similar measure of port match to return loss but is a scalar linear quantity, the ratio of the standing wave maximum voltage to the standing wave minimum voltage.

  4. Signal reflection - Wikipedia

    en.wikipedia.org/wiki/Signal_reflection

    If only reflection magnitudes are desired, however, and exact fault locations are not required, VSWR bridges perform a similar but lesser function for RF cables. The combination of the effects of signal attenuation and impedance discontinuities on a communications link is called insertion loss.

  5. Reflections of signals on conducting lines - Wikipedia

    en.wikipedia.org/wiki/Reflections_of_signals_on...

    A time-domain reflectometer; an instrument used to locate the position of faults on lines from the time taken for a reflected wave to return from the discontinuity.. A signal travelling along an electrical transmission line will be partly, or wholly, reflected back in the opposite direction when the travelling signal encounters a discontinuity in the characteristic impedance of the line, or if ...

  6. Attenuator (electronics) - Wikipedia

    en.wikipedia.org/wiki/Attenuator_(electronics)

    Attenuation expressed in decibels of relative power. A 3 dB pad reduces power to one half, 6 dB to one fourth, 10 dB to one tenth, 20 dB to one hundredth, 30 dB to one thousandth and so on. A 3 dB pad reduces power to one half, 6 dB to one fourth, 10 dB to one tenth, 20 dB to one hundredth, 30 dB to one thousandth and so on.

  7. Propagation constant - Wikipedia

    en.wikipedia.org/wiki/Propagation_constant

    In telecommunications, the term attenuation constant, also called attenuation parameter or attenuation coefficient, is the attenuation of an electromagnetic wave propagating through a medium per unit distance from the source. It is the real part of the propagation constant and is measured in nepers per metre.

  8. Return loss - Wikipedia

    en.wikipedia.org/wiki/Return_loss

    In telecommunications, return loss is a measure in relative terms of the power of the signal reflected by a discontinuity in a transmission line or optical fiber.This discontinuity can be caused by a mismatch between the termination or load connected to the line and the characteristic impedance of the line.

  9. Waveguide - Wikipedia

    en.wikipedia.org/wiki/Waveguide

    An impedance mismatch can be also quantified with the standing wave ratio (SWR or VSWR for voltage), which is connected to the impedance ratio and reflection coefficient by: = | | | | = + | | | |, where | | / are the minimum and maximum values of the voltage absolute value, and the VSWR is the voltage standing wave ratio, which value of 1 ...