  1. Results from the WOW.Com Content Network
  2. Molar absorption coefficient - Wikipedia

    en.wikipedia.org/wiki/Molar_absorption_coefficient

    c is the molar concentration of those species; ℓ is the path length. Different disciplines have different conventions as to whether absorbance is decadic (10-based) or Napierian (e-based), i.e., defined with respect to the transmission via common logarithm (log 10) or a natural logarithm (ln). The molar absorption coefficient is usually decadic.

  3. Isosbestic point - Wikipedia

    en.wikipedia.org/wiki/Isosbestic_point

    The spectra of basic, acid and intermediate pH solutions are shown. The analytical concentration of the dye is the same in all solutions. In spectroscopy, an isosbestic point is a specific wavelength, wavenumber or frequency at which the total absorbance of a sample does not change during a chemical reaction or a physical change of the sample ...

  4. Reaction progress kinetic analysis - Wikipedia

    en.wikipedia.org/wiki/Reaction_progress_kinetic...

    where [A] 0 is the amount, absorbance, or concentration of substrate initially present and [A] t is the amount, absorbance, or concentration of that reagent at time, t. Normalizing data to fractional conversion may be particularly helpful as it allows multiple reactions run with different absolute amounts or concentrations to be compared on the ...

  5. Bradford protein assay - Wikipedia

    en.wikipedia.org/wiki/Bradford_protein_assay

    The equation displayed on the chart gives a means for calculating the absorbance and therefore concentration of the unknown samples. In Graph 1, x is concentration and y is absorbance, so one must rearrange the equation to solve for x and enter the absorbance of the measured unknown. [25]

  6. Bjerrum plot - Wikipedia

    en.wikipedia.org/wiki/Bjerrum_plot

    Example Bjerrum plot: Change in carbonate system of seawater from ocean acidification.. A Bjerrum plot (named after Niels Bjerrum), sometimes also known as a Sillén diagram (after Lars Gunnar Sillén), or a Hägg diagram (after Gunnar Hägg) [1] is a graph of the concentrations of the different species of a polyprotic acid in a solution, as a function of pH, [2] when the solution is at ...

  7. Calibration curve - Wikipedia

    en.wikipedia.org/wiki/Calibration_curve

    A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]

  8. pH indicator - Wikipedia

    en.wikipedia.org/wiki/PH_indicator

    For example, if the concentration of the conjugate base is 10 times greater than the concentration of the acid, their ratio is 10:1, and consequently the pH is pK a + 1 or pK b + 1. Conversely, if a 10-fold excess of the acid occurs with respect to the base, the ratio is 1:10 and the pH is p K a − 1 or p K b − 1.

  9. pH - Wikipedia

    en.wikipedia.org/wiki/PH

    The pH of a solution is defined as the negative logarithm of the concentration of H+, and the pOH is defined as the negative logarithm of the concentration of OH-. For example, the pH of a 0.01M solution of hydrochloric acid (HCl) is equal to 2 (pH = −log 10 (0.01)), while the pOH of a 0.01M solution of sodium hydroxide (NaOH) is equal to 2 ...