Search results
Results from the WOW.Com Content Network
The first blower door was further used to test the airtightness of the Saskatchewan Conservation House built in 1977, which was tested at 0.5 ach at 50 Pa. These early research efforts demonstrated the potential power of blower door testing in revealing otherwise unaccounted for energy losses in homes.
A third test method to determine if ductwork is leaking to the outside is to use a pressure pan, which is a register cover with a pressure tap for a hose connection. With the house pressurized (or depressurized) to 50 Pa (-50 Pa) using a blower door, a pressure gauge is attached to the pressure pan by means of a hose.
The most common technique to measure airtightness is the fan pressurization method, also known as the blower door test. It is measured by the number of air changes per hour (ACH) that occur when there is a differential pressure of 50 pascals between outside and inside the building.
Performance testing, such as a blower door test for air leakage, outside and total duct leakage, and mechanical ventilation testing is usually part of the rating. Confirmed, Sampled, and Threshold Ratings that are built above code requirements are registered with public databases such as the RESNET Registry [8] and the BSI Registry. [9]
In heating, ventilation, and air conditioning (HVAC), testing, adjusting and balancing (TAB) are the three major steps used to achieve proper operation of heating, ventilation, and air conditioning systems. TAB usually refers to commercial building construction and the specialized contractors who employ personnel that perform this service.
A blower door test can be used to test the quality of the air sealing of the building envelope. Smoke pencils can be used to detect gaps and caulking and weather-stripping can be used to improve air sealing. [10]
Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!
Smoke candles and blower-door tests can help identify less-than-obvious leaks. The Weatherization article describes methods for energy savings further. If infiltration is reduced below 0.35 ACH, it is recommended that mechanical ventilation (typically an exhaust fan or heat recovery ventilation ) be implemented.