enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Shop drawing - Wikipedia

    en.wikipedia.org/wiki/Shop_drawing

    A specific number of copies may be required by the specification. An example distribution of the completed and corrected shop drawings may include the: Owner—file or inspection copy; Architect—file copy; Architect—field copy or inspection copy; Consulting engineer—file copy; Consulting engineer—inspection copy; Contractor—file copy

  3. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The CLTD/CLF/SCL (cooling load temperature difference/cooling load factor/solar cooling load factor) cooling load calculation method was first introduced in the 1979 ASHRAE Cooling and Heating Load Manual (GRP-158) [1] The CLTD/CLF/SCL Method is regarded as a reasonably accurate approximation of the total heat gains through a building envelope ...

  4. ASHRAE Handbook - Wikipedia

    en.wikipedia.org/wiki/ASHRAE_Handbook

    The Handbook's content is created and modified by volunteers via ASHRAE's many Technical Committees (TCs), and then edited and formatted by professional staff at ASHRAE. For example, three chapters, in three different volumes, are maintained by TC 5.3, Room Air Distribution.

  5. Submittals (construction) - Wikipedia

    en.wikipedia.org/wiki/Submittals_(construction)

    The product data submittal usually consists of the manufacturer's product information. The information included in this submittal are: Manufacturer, trade name, model or type number and quantities: This information is necessary to compare the submitted item with the specified products and acceptable products listed, in the specification and addenda.

  6. 16 Divisions - Wikipedia

    en.wikipedia.org/wiki/16_Divisions

    The 16 Divisions of construction, as defined by the Construction Specifications Institute (CSI)'s MasterFormat, is the most widely used standard for organizing specifications and other written information for commercial and institutional building projects in the U.S. and Canada.

  7. MasterFormat - Wikipedia

    en.wikipedia.org/wiki/MasterFormat

    MasterFormat is a standard for organizing specifications and other written information for commercial and institutional building projects in the U.S. and Canada. [1] Sometimes referred to as the "Dewey Decimal System" of building construction, MasterFormat is a product of the Construction Specifications Institute (CSI) and Construction Specifications Canada (CSC).

  8. Demand controlled ventilation - Wikipedia

    en.wikipedia.org/wiki/Demand_controlled_ventilation

    However, such spaces are not always fully occupied; in these cases, energy is wasted as the HVAC system processes more OA than is necessary for the space occupants. [3] Demand control ventilation is an attractive alternative to standard design in these situations because DCV systems only supply the outdoor airflow necessary to serve the ...

  9. Heat recovery ventilation - Wikipedia

    en.wikipedia.org/wiki/Heat_recovery_ventilation

    Diagramatic operation of a thermal wheel Ljungström Air Preheater by Swedish engineer Fredrik Ljungström (1875–1964). A thermal wheel, also known as a rotary heat exchanger, or rotary air-to-air enthalpy wheel, energy recovery wheel, or heat recovery wheel, is a type of energy recovery heat exchanger positioned within the supply and exhaust air streams of air-handling units or rooftop ...