enow.com Web Search

  1. Ads

    related to: load bank testing a generator

Search results

  1. Results from the WOW.Com Content Network
  2. Load bank - Wikipedia

    en.wikipedia.org/wiki/Load_bank

    A load bank is a piece of electrical test equipment used to simulate an electrical load, to test an electric power source without connecting it to its normal operating load. [ 1 ] [ 2 ] During testing, adjustment, calibration, or verification procedures, a load bank is connected to the output of a power source, such as an electric generator ...

  3. Dummy load - Wikipedia

    en.wikipedia.org/wiki/Dummy_load

    These may be used, for example, for factory and in-service testing of standby generators. A load bank may be used to stabilize a power system in case of loss of load, for example, on an isolated wind or mini-hydro plant. An electronic load (or e-load) is a device or assembly that simulates loading on an electronic circuit. It is used as ...

  4. Liquid rheostat - Wikipedia

    en.wikipedia.org/wiki/Liquid_rheostat

    Railways commonly used salt water load banks in the 1950s to test the output power of diesel-electric locomotives. [3] They were subsequently replaced by specially designed resistive load banks. Some early three-phase AC electric locomotives also used liquid rheostats for starting up the motors and balancing load between multiple locomotives. [4]

  5. Dynamic braking - Wikipedia

    en.wikipedia.org/wiki/Dynamic_braking

    It is possible to use the brake grids as a form of dynamometer or load bank to perform a self-load test of the power output of a locomotive. With the locomotive stationary, the main generator (MG) output is connected to the grids instead of the traction motors.

  6. Diesel generator - Wikipedia

    en.wikipedia.org/wiki/Diesel_generator

    A specific model of a generator operated as a standby generator may only need to operate for a few hours per year, but the same model operated as a prime power generator must operate continuously. When running, the standby generator may be operated with a specified - e.g. 10% overload that can be tolerated for the expected short running time.

  7. AOL Mail

    mail.aol.com

    Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!

  8. Discover the best free online games at AOL.com - Play board, card, casino, puzzle and many more online games while chatting with others in real-time.

  9. Induction generator - Wikipedia

    en.wikipedia.org/wiki/Induction_generator

    If the load also absorbs reactive power, capacitor bank must be increased in size to compensate. Prime mover speed should be used to generate frequency of 60 Hz: Typically, slip should be similar to full-load value when machine is running as motor, but negative (generator operation): if Ns = 1800, one can choose N=Ns+40 rpm

  1. Ads

    related to: load bank testing a generator