This image is of the angle of the eye as seen through a slit lamp. It is labelled as Grade 4 according to Van Herick's Grading system. The Van Herick's technique compares the depth of the peripheral anterior chamber with the cornea thickness, usually written as a fraction [ 6 ] however, it can also be expressed as a ratio (see table 3). [ 5 ]
In ophthalmology, gonioscopy is a routine procedure that measures the angle between the iris and the cornea (the iridocorneal angle), using a goniolens (also known as a gonioscope) together with a slit lamp or operating microscope. [1] [2] Its use is important in diagnosing and monitoring various eye conditions associated with glaucoma.
Eye examination with the aid of a slit lamp. Side view of a slit lamp machine. Cataract in human eye: magnified view seen on examination with the slit lamp. In ophthalmology and optometry, a slit lamp is an instrument consisting of a high-intensity light source that can be focused to shine a thin sheet of light into the eye.
Slit lamp bio microscope: used for examining the anteriorly placed structures the eye; video link: Charts for vision - •Distant vision: to determine visual acuity of distant vision ••Snellen's distant vision chart-do-; for those who can read in English ••Regional language charts-do-; for those who can read in their local language ...
The slit lamp also allows inspection of all the ocular media, from cornea to vitreous, plus magnified view of eyelids, and other external ocular related structures. Fluorescein staining of the tear film before slit lamp examination may reveal etiologies of the surface of the eye, such as corneal abrasions or keratitis due to herpes simplex ...
Slit lamp examination SLM Slit lamp microscope EP Esophoria: ET Esotropia: Supp. Suppression V Vision (unaided) VA Visual acuity VA Dcc - VA Dsc Visual acuity with Distant chart with correctors Visual acuity with eye chart at Distant 20 feet (6 m) and with (cc: Latin cum correctore) correctors (spectacles); Dsc is without (sc: Latin sine ...
If you’re stuck on today’s Wordle answer, we’re here to help—but beware of spoilers for Wordle 1269 ahead. Let's start with a few hints.
Watzke-Allen test is done by projecting a thin line of light over the macula with a slit lamp. [4] A fundus lens or macular lens is used to aim beam of light on the macula. [5] It is best performed in a dilated eye, projecting a slit beam of approximately 100 μm. The slit is projected in both vertical and horizontal orientations. [6]