A proof test is a form of stress test to demonstrate the fitness of a load-bearing or impact-experiencing structure. An individual proof test may apply only to the unit tested, or to its design in general for mass-produced items. Such a structure is often subjected to loads above those expected in actual use, demonstrating safety and design margin.
The formal definition of calibration by the International Bureau of Weights and Measures (BIPM) is the following: "Operation that, under specified conditions, in a first step, establishes a relation between the quantity values with measurement uncertainties provided by measurement standards and corresponding indications with associated measurement uncertainties (of the calibrated instrument or ...
Metrology is defined as the science of weights & measures, while a PMEL is the place where technicians perform all of the metrology for the U.S. Air Force. Air personnel in this career field are primarily responsible for the repair, calibration, and modification of test, measurement, and diagnostic equipment (TMDE), including precision ...
Calibration is conducted incrementally starting working in ascending or descending order. For example, in the case of a 60 tonne load cell, then specific test weights that measure in 5, 10, 20, 40 and 60 tonne increments may be used; a five step calibration process is usually sufficient for ensuring a device is accurately calibrated.
This developing system of international mutual recognition agreements between accreditation bodies has enabled accredited laboratories to achieve a form of international recognition, and allowed test data accompanying exported goods to be readily accepted on overseas markets amongst the countries which have already qualified as significant to ...
ISO/IEC 17025 General requirements for the competence of testing and calibration laboratories is the main standard used by testing and calibration laboratories. In most countries, ISO/IEC 17025 is the standard for which most labs must hold accreditation in order to be deemed technically competent.
The weights and balances used in local markets and other areas are expected to be certified by the Department of Weights and Measures of the local government. Working standards of these local departments should, in turn, be calibrated against the state level standards or any other laboratory which is entitled to do so.
A dead weight tester (DWT) is a calibration standard method that uses a piston cylinder on which a load is placed to make an equilibrium with an applied pressure underneath the piston. Deadweight testers are secondary standards which means that the pressure measured by a deadweight tester is defined through other quantities: length, mass and time.