Dusts also have upper and lower explosion limits, though the upper limits are hard to measure and of little practical importance. Lower flammability limits for many organic materials are in the range of 10–50 g/m 3, which is much higher than the limits set for health reasons, as is the case for the LEL of many gases and vapours. Dust clouds ...
Any stoichiometric mixture of methane and oxygen will lie on the straight line between pure nitrogen (and zero percent methane) and 33 percent methane (and 67 percent oxygen) – this is shown as the red stoichiometric line. The upper and lower flammability limits of methane in oxygen are located on the methane axis, as shown.
The lower flammability limit or lower explosive limit (LFL/LEL) represents the lowest air to fuel vapor concentration required for combustion to take place when ignited by an external source, for any particular chemical. [29] Any concentration lower than this could not produce a flame or result in combustion.
The lower flammability limit (LFL), [1] usually expressed in volume per cent, is the lower end of the concentration range over which a flammable mixture of gas or vapour in air can be ignited at a given temperature and pressure. The flammability range is delineated by the upper and lower flammability limits. Outside this range of air/vapor ...
Only pure chemicals belong here not fuel air mixtures to be here a gas must have an upper explosive limit of 100%. Pages in category "Explosive gases" The following 9 pages are in this category, out of 9 total.
In order to properly inert or purge, the flammability limits must be taken into account, and hydrogen's are very different from other kinds of gases. At normal atmospheric pressure it is 4% to 75%, based on the volume percent of hydrogen in oxygen it is 4% to 94%, while the limits of the detonation potential of hydrogen in air are 18.3% to 59% ...
For each fuel, ignition occurs only within a certain range of concentration, known as the upper and lower flammability limits. For example, for methane and gasoline vapor, this range is 5-15% and 1.4-7.6% gas to air, respectively. An explosion can only occur when fuel concentration is within these limits [citation needed]
Oldham EX2000 portable explosimeter. An explosimeter is a gas detector which is used to measure the amount of combustible gases present in a sample. When a percentage of the lower explosive limit (LEL) of an atmosphere is exceeded, an alarm signal on the instrument is activated.