AWG is colloquially referred to as gauge and the zeros in thick wire sizes are referred to as aught / ˈ ɔː t /. Wire sized 1 AWG is referred to as "one gauge" or "No. 1" wire; similarly, thinner sizes are pronounced "x gauge" or "No. x" wire, where x is the positive-integer AWG number. Consecutive AWG wire sizes thicker than No. 1 wire are ...
Each notch is stamped with a number, and the wire or sheet, which just fits a given notch, is stated to be of, say, No. 10, 11, 12, etc., of the wire gauge. The circular forms of wire gauge measurement devices are the most popular, and are generally 3 + 3 ⁄ 4 inches (95 mm) in diameter, with thirty-six notches; many have the decimal ...
Each size of wire in the American Wire Gauge is related to its neighboring wire sizes by the ratio 1.122932. (See footnote for the derivation of this value). For example, 0 (zero) gauge wire has a diameter of 0.3249 inches and the next smaller wire (1 gauge) has a diamter of 0.3249 / 1.122932 ~= 0.2893 inches.
A standard wire gauge. The British Standard Wire Gauge, often referred to as the Standard Wire Gauge or simply SWG, is a unit used to denote wire gauge (size) as defined by BS 3737:1964, a standard that has since been withdrawn. It is also known as the Imperial Wire Gauge or British Standard Gauge. Although its use has significantly declined ...
Cross-sectional area of electrical wire is measured in circular mils in the U.S. and Canada, one circular mil (cmil) being equal to 5.067 × 10 −4 mm 2 (or 7.854 × 10 −7 in 2). Since this is so small, actual wire is commonly measured in thousands of a cmil, called either kcmil or MCM. The mil or thou is also sometimes used to mean ...
In both those instances the white wire should be identified as being hot, usually with black tape inside junction boxes. The neutral wire is identified by gray or white insulated wire, perhaps using stripes or markings. With lamp cord wire the ribbed wire is the neutral, and the smooth wire is the hot. NEC 2008 400.22(f) allows surface marking ...
Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...
The amount of current a cable or wire can safely carry depends on the installation conditions. The international standard wire sizes are given in the IEC 60228 standard of the International Electrotechnical Commission. In North America, the American Wire Gauge standard for wire sizes is used.