[2] Some codes require a bonding jumper to be pulled into non-metallic conduit or in electrical metallic tubing that may be exposed to corrosion or mechanical damage. In North American electrical codes, an important bonding jumper is found in main electrical panels, where the system neutral conductor is connected to earth ground. This must be ...
A similar bonding jumper wire is used between the inlet and outlet of gas meters, but here the purpose is to avoid having a substantial voltage difference between the building’s grounding electrode(s) and buried natural gas lines appear across the gas meter during the brief interval when a line to ground fault is conducting before the ...
One side is connected to a flexible supply hose; the other may be attached to a manifold, valve, tool, or another hose. A female coupler is used on the supply side, and a male nipple is used on the receiving side. Fitting profiles have identifiable geometry on the male end, but care must be taken to use a compatible coupler.
Compression connectors on an isolating valve; the reddish part is a copper compression ring Compression fittings (sometimes called "lock-bush fittings") consist of a tapered, concave conical seat; a hollow, barrel-shaped compression ring (sometimes called a ferrule); and a compression nut which is threaded onto the body of the fitting and ...
Grounding connectors. Connectors for earthing installation are a means of communication between the various components of the earthing and lightning protection installations (earthing rods, earthing conductors, current leads, busbars, etc.). For high voltage installations, exothermic welding is used for underground connections.
The ground tab is designed to be attached to the outlet faceplate screw, which is supposed to be connected to the building electrical ground. A cheater plug, AC ground lifter or three-prong/two-prong adapter is an adapter that allows a NEMA 5-15P grounding-type plug (three prongs) to connect to a NEMA 1-15R non-grounding receptacle (two slots).
Strictly speaking, the terms grounding or earthing are meant to refer to an electrical connection to ground/earth. Bonding is the practice of intentionally electrically connecting metallic items not designed to carry electricity. This brings all the bonded items to the same electrical potential as a protection from electrical shock.
A ground connection that is missing or of inadequate capacity may not provide the protective functions as intended during a fault in the connected equipment. Extra connections between ground and circuit neutral may result in circulating current in the ground path, stray current introduced in the earth or in a structure, and stray voltage.