enow.com Web Search

  1. Ads

    related to: carrier 4 ton heat pump condenser fan not running

Search results

  1. Results from the WOW.Com Content Network
  2. Heat pump and refrigeration cycle - Wikipedia

    en.wikipedia.org/wiki/Heat_pump_and...

    Vapor-compression refrigeration [6] For comparison, a simple stylized diagram of a heat pump's vapor-compression refrigeration cycle: 1) condenser, 2) expansion valve, 3) evaporator, 4) compressor (Note that this diagram is flipped vertically and horizontally compared to the previous one) [7] Temperature–entropy diagram of the vapor-compression cycle.

  3. Crankcase heater - Wikipedia

    en.wikipedia.org/wiki/Crankcase_heater

    A crankcase heater is an electrical component in a compressor in an air-conditioning system, heat pump system, or chiller system. The crankcase heater is normally on all the time, even when the unit is not running, though temperature sensors and set points may turn it off when not needed.

  4. Fan coil unit - Wikipedia

    en.wikipedia.org/wiki/Fan_coil_unit

    These motors are sometimes called DC motors, sometimes EC motors and occasionally DC/EC motors. DC stands for direct current and EC stands for electronically commutated.. DC motors allow the speed of the fans within a fan coil unit to be controlled by means of a 0-10 Volt input control signal to the motor/s, the transformers and speed switches associated with AC fan coils are not required.

  5. Air conditioning - Wikipedia

    en.wikipedia.org/wiki/Air_conditioning

    The heat pump is significantly more energy-efficient than electric resistance heating, because it moves energy from air or groundwater to the heated space and the heat from purchased electrical energy. When the heat pump is in heating mode, the indoor evaporator coil switches roles and becomes the condenser coil, producing heat.

  6. Heat pump - Wikipedia

    en.wikipedia.org/wiki/Heat_pump

    An international milestone is the heat pump built by Escher Wyss in 1937/38 to replace the wood stoves in the City Hall of Zurich. To avoid noise and vibrations, a recently developed rotary piston compressor was used. This historic heat pump heated the town hall for 63 years until 2001. Only then was it replaced by a new, more efficient heat ...

  7. Motor capacitor - Wikipedia

    en.wikipedia.org/wiki/Motor_capacitor

    Motor capacitors are used with single-phase electric motors [3]: 11 that are in turn used to drive air conditioners, hot tub/jacuzzi spa pumps, powered gates, large fans or forced-air heat furnaces for example. [1] A "dual run capacitor" is used in some air conditioner compressor units, to boost both the fan and compressor motors. [1]

  8. Ground source heat pump - Wikipedia

    en.wikipedia.org/wiki/Ground_source_heat_pump

    A heat pump in combination with heat and cold storage. A ground source heat pump (also geothermal heat pump) is a heating/cooling system for buildings that use a type of heat pump to transfer heat to or from the ground, taking advantage of the relative constancy of temperatures of the earth through the seasons.

  9. Affinity laws - Wikipedia

    en.wikipedia.org/wiki/Affinity_laws

    The affinity laws (also known as the "Fan Laws" or "Pump Laws") for pumps/fans are used in hydraulics, hydronics and/or HVAC to express the relationship between variables involved in pump or fan performance (such as head, volumetric flow rate, shaft speed) and power. They apply to pumps, fans, and hydraulic turbines. In these rotary implements ...

  1. Ads

    related to: carrier 4 ton heat pump condenser fan not running