enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Actual cubic feet per minute - Wikipedia

    en.wikipedia.org/wiki/Actual_cubic_feet_per_minute

    Ratings found in centrifugal fan performance tables and curves are based on standard cubic feet per minute (SCFM). Fan manufacturers define standard air as clean, dry air with a density of 0.075 pounds mass per cubic foot, with the atmospheric pressure at sea level of 29.92 inches of mercury and a temperature of 70°F.

  3. High-volume low-speed fan - Wikipedia

    en.wikipedia.org/wiki/High-volume_low-speed_fan

    The air column from a 3-foot-diameter (0.91 m) fan, therefore, has more than six times as much friction interface per volume of air moved as does the air column from a 20-foot-diameter (6.1 m) fan. [8] When the down column of air from an HVLS fan reaches the floor, the air turns in the horizontal direction away from the column in all directions.

  4. Centrifugal fan - Wikipedia

    en.wikipedia.org/wiki/Centrifugal_fan

    Figure 1: Components of a centrifugal fan An external motor belt driven inline centrifugal fan discharging inline to the exterior of a building through a duct. Unlike non-inline/non-concentric impeller casing design with a cutoff blade above, the concentrically symetric cylinder casing and impeller geometry of inline type redirects the outflow around so that it is parallel to the inflow of gases.

  5. Axial fan design - Wikipedia

    en.wikipedia.org/wiki/Axial_fan_design

    An axial fan is a type of fan that causes gas to flow through it in an axial direction, parallel to the shaft about which the blades rotate. The flow is axial at entry and exit. The fan is designed to produce a pressure difference, and hence force, to cause a flow through the fan. Factors which determine the performance of the fan include the ...

  6. Heating, ventilation, and air conditioning - Wikipedia

    en.wikipedia.org/wiki/Heating,_ventilation,_and...

    Air-side economizers also use outside air to condition spaces, but do so using fans, ducts, dampers, and control systems to introduce and distribute cool outdoor air when appropriate. An important component of natural ventilation is air change rate or air changes per hour : the hourly rate of ventilation divided by the volume of the space.

  7. Fan (machine) - Wikipedia

    en.wikipedia.org/wiki/Fan_(machine)

    The cross-flow or tangential fan, sometimes known as a tubular fan, was patented in 1893 by Paul Mortier, [17] [18] and is used extensively in heating, ventilation, and air conditioning (HVAC), especially in ductless split air conditioners. The fan is usually long relative to its diameter, so the flow remains approximately two-dimensional away ...

  8. Specific fan power - Wikipedia

    en.wikipedia.org/wiki/Specific_fan_power

    is the gross amount of air circulated through the fan (or ventilation system) [m 3 /s] There are various sub-definitions of SFP for different specific applications, including SFP e (building energy performance calculations), SFP v (for performance verification tests), SFP i (individual fan), SFP AHU (air handling unit), SFP FCU (fan coil unit ...

  9. Standard cubic feet per minute - Wikipedia

    en.wikipedia.org/wiki/Standard_cubic_feet_per_minute

    To further confuse the issue, a centrifugal fan is a constant CFM device or a constant volume device. This means that, provided the fan speed remains constant, a centrifugal fan will pump a constant volume of air. This is not the same as pumping a constant mass of air. Again, the fan will pump the same volume, though not mass, at any other air ...