enow.com Web Search

  1. Ad

    related to: ibc fire escape requirements for construction contractors manual

Search results

  1. Results from the WOW.Com Content Network
  2. Smokeproof enclosure - Wikipedia

    en.wikipedia.org/wiki/Smokeproof_enclosure

    For fully sprinkled buildings, the required rating is just one hour.) [4] The fans must be connected to an emergency power supply, and capable of both automatic activation by various fire and smoke detectors, and of manual activation by a central command post or by the actuation of a general fire alarm.

  3. Fire escape - Wikipedia

    en.wikipedia.org/wiki/Fire_escape

    The use of a fire escape is dictated by various local, state, and agreed-upon international building codes, such as standards provided by the International Code Council (ICC), the International Building Code (IBC), or the International Energy Conservation Code. Both the 2012 IBC and 2012 IRC require emergency escape and rescue openings for ...

  4. Heat and smoke vent - Wikipedia

    en.wikipedia.org/wiki/Heat_and_smoke_vent

    The majority of guidance available for design of heat and smoke building vents installed in buildings is restricted to nonsprinklered, single-story buildings. [4] This is partly a historical consequence of the installation of heat and smoke vents following the August 1953 General Motors, Livonia, MI major fire in a nonsprinklered manufacturing facility which effectively stopped the production ...

  5. International Code Council - Wikipedia

    en.wikipedia.org/wiki/International_Code_Council

    A large portion of the International Building Code deals with fire prevention. It differs from the related International Fire Code in that the IBC addresses fire prevention in regard to construction and design and the fire code addresses fire prevention in regard to the operation of a completed and occupied building. For example, the building ...

  6. Building code - Wikipedia

    en.wikipedia.org/wiki/Building_code

    Fire code rules to minimize the risk of a fire and to ensure safe evacuation in the event of such an emergency [citation needed] Requirements for earthquake (seismic code), hurricane, flood, and tsunami resistance, especially in disaster prone areas or for very large buildings where a failure would be catastrophic [citation needed]

  7. Fire blocking - Wikipedia

    en.wikipedia.org/wiki/Fire_blocking

    Fire blocking may also serve as bridging between framing elements, stiffening them against lateral buckling. [4] [5] Fire blocking or firestopping terminology was used interchangeably in code language from its first mention in the 1905 National Building Code (NBC), and requirements were expanded in the 1927 Uniform Building Code (UBC). Building ...

  8. Smoke exhaust ductwork - Wikipedia

    en.wikipedia.org/wiki/Smoke_exhaust_ductwork

    Smoke exhaust ductwork, in Europe, is typically protected via passive fire protection means, subject to fire testing (typically to NBN EN 1366-8 [1]) and listing and approval use and compliance. It is used to remove smoke from buildings , ships or offshore structures to enable emergency evacuation as well as improved firefighting.

  9. Smoke damper - Wikipedia

    en.wikipedia.org/wiki/Smoke_damper

    Smoke damper may be used to prevent the spread of smoke from the space of fire origin to other spaces in the same building. A combination of fans and dampers can exhaust smoke from an area while pressurizing the smoke-free areas around the affected area (inhibiting smoke infiltration into additional areas).

  1. Ad

    related to: ibc fire escape requirements for construction contractors manual