enow.com Web Search

  1. Ads

    related to: how to calibrate analytical balance test

Search results

  1. Results from the WOW.Com Content Network
  2. Calibration curve - Wikipedia

    en.wikipedia.org/wiki/Calibration_curve

    A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]

  3. Analytical balance - Wikipedia

    en.wikipedia.org/wiki/Analytical_balance

    An analytical balance (or chemical balance) is a class of balance designed to measure small mass in the sub-milligram range. The measuring pan of an analytical balance (0.1 mg resolution or better) is inside a transparent enclosure with doors so that dust does not collect and so any air currents in the room do not affect the balance's operation.

  4. Certified reference materials - Wikipedia

    en.wikipedia.org/wiki/Certified_reference_materials

    Certified reference materials (CRMs) are 'controls' or standards used to check the quality and metrological traceability of products, to validate analytical measurement methods, or for the calibration of instruments. [1] A certified reference material is a particular form of measurement standard.

  5. Calibration - Wikipedia

    en.wikipedia.org/wiki/Calibration

    The formal definition of calibration by the International Bureau of Weights and Measures (BIPM) is the following: "Operation that, under specified conditions, in a first step, establishes a relation between the quantity values with measurement uncertainties provided by measurement standards and corresponding indications with associated measurement uncertainties (of the calibrated instrument or ...

  6. Internal standard - Wikipedia

    en.wikipedia.org/wiki/Internal_standard

    The calibration curve that does not use the internal standard method ignores the uncertainty between measurements. The coefficient of determination (R 2 ) for this plot is 0.9985. In the calibration curve that uses the internal standard, the y-axis is the ratio of the nickel signal to the yttrium signal.

  7. Gravimetric analysis - Wikipedia

    en.wikipedia.org/wiki/Gravimetric_analysis

    Gravimetric analysis describes a set of methods used in analytical chemistry for the quantitative determination of an analyte (the ion being analyzed) based on its mass. The principle of this type of analysis is that once an ion's mass has been determined as a unique compound, that known measurement can then be used to determine the same analyte's mass in a mixture, as long as the relative ...

  8. Analytical quality control - Wikipedia

    en.wikipedia.org/wiki/Analytical_quality_control

    All analytical procedures should be validated. Identification tests are conducted to ensure the identity of an analyte in a sample through comparison of the sample to a reference standard through methods such as spectrum, chromatographic behavior, and chemical reactivity. [5] Impurity testing can either be a quantitative test or a limit test.

  9. Microbalance - Wikipedia

    en.wikipedia.org/wiki/Microbalance

    A microbalance is an instrument capable of making precise measurements of weight of objects of relatively small mass: of the order of a million parts of a gram.In comparison, a standard analytical balance is 100 times less sensitive; i.e. it is limited in precision to 0.1 milligrams.

  1. Ads

    related to: how to calibrate analytical balance test