This is a list of insulation materials used around the world. Typical R-values are given for various materials and structures as approximations based on the average of available figures and are sorted by lowest value. R-value at 1 m gives R-values normalised to a 1 metre (3 ft 3 in) thickness and sorts by median value of the range.
Installed faced fiberglass batt insulation with its R-value visible (R-21) [1]. The R-value is a measure of how well a two-dimensional barrier, such as a layer of insulation, a window or a complete wall or ceiling, resists the conductive [2] flow of heat, in the context of construction. [3]
Compressed straw bales have a wide range of documented R-value. R-value is a measurement of a materials insulating quality, higher the number the more insulating. The reported R-value ranges from 17–55 (in American units) or 3–9.6 (in SI) depending on the study, differing wall designs could be responsible for wide range in R-value.
The Straw Bale House, 1994). Using a straw bale in-fill sandwich roof greatly increases the R value. This compares very favorably with the R-19 (RSI-3.35) of a conventional 2 x 6 insulated wall. When using straw bales for construction, the bales must be tightly-packed and allowed to dry out sufficiently.
This means that VIPs have about one-fifth the thermal conductivity of conventional insulation, and therefore about five times the thermal resistance per unit thickness. Based on a typical k-value of 0.007 W/(m·K), the R-value of a typical 25-millimetre-thick (1 in) VIP would be 3.5 m 2 ·K/W (20 h·ft 2 ·°F/BTU). To provide the same R-value ...
EPS is the most common of the foams used and has an R-value (thermal resistance) of about 4 °F·ft 2 ·h/Btu (equivalent to about 0.7 K·m 2 /W) per 25 mm thickness, which would give the 3.5 inches (89 mm) of foam in a 4.5-inch-thick (110 mm) panel an R value of 13.8 (caution: extrapolating R-values over thickness may be imprecise due to non ...
Producers report an average R-value of 2.0 - 5.5, significantly more than that of other siding products including fiber cement, brick and stucco. Homeowners also report insulated siding serves as a noise barrier to external sound. Insulated vinyl siding with added fan fold foam board insulation raises the R-value to 3.5 - 7.5.
Many builders in northern Canada use a simple 1/3 to 2/3 approach, placing the vapor barrier no further out than 1/3 of the R-value of the insulated portion of the wall. This method is generally valid for interior walls with little or no vapor resistance (e.g., they use fibrous insulation) and controls air leakage condensation and vapor ...