Search results

  1. Results from the WOW.Com Content Network
  2. IEC 60228 - Wikipedia

    en.wikipedia.org/wiki/IEC_60228

    Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...

  3. Ampacity - Wikipedia

    en.wikipedia.org/wiki/Ampacity

    For example, the United States National Electrical Code, Table 310.15(B)(16), specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30 °C, the conductor surface temperature allowed to be 75 °C. A single insulated conductor ...

  4. Neher–McGrath method - Wikipedia

    en.wikipedia.org/wiki/Neher–McGrath_method

    By estimating the temperature of the cables, the safe long-term current-carrying capacity of the cables can be calculated. J. H. Neher and M. H. McGrath were two electrical engineers who wrote a paper in 1957 about how to calculate the capacity of current (ampacity) of cables. [ 1 ]

  5. American wire gauge - Wikipedia

    en.wikipedia.org/wiki/American_wire_gauge

    Manufacturers of wire formerly had proprietary wire gauge systems; the development of standardized wire gauges rationalized selection of wire for a particular purpose. While the AWG is essentially identical to the Brown & Sharpe (B&S) sheet metal gauge, the B&S gauge was designed for use with sheet metals as its name suggests.

  6. Extra-low voltage - Wikipedia

    en.wikipedia.org/wiki/Extra-low_voltage

    The higher current results in greater resistive losses in the cabling. Cable sizing must therefore consider maximum demand, voltage drop over the cable, and current-carrying capacity . Voltage drop is usually the main factor considered, but current-carrying capacity is as important when considering short, high-current runs such as between a ...

  7. Dynamic line rating for electric utilities - Wikipedia

    en.wikipedia.org/wiki/Dynamic_line_rating_for...

    Electric current passing through the conductor causes heating according to Joule's first law, resulting in the conductor expanding and the line sagging. Transmission ratings are set with a maximum allowable conductor temperature (annealing temperature) and minimum clearance rules to comply with legislation and regulation. [1]

  8. Copper conductor - Wikipedia

    en.wikipedia.org/wiki/Copper_conductor

    [1] [2] The invention of the telephone in 1876 created further demand for copper wire as an electrical conductor. [3] Copper is the electrical conductor in many categories of electrical wiring. [3] [4] Copper wire is used in power generation, power transmission, power distribution, telecommunications, electronics circuitry, and countless types ...

  9. Electrical conductor - Wikipedia

    en.wikipedia.org/wiki/Electrical_conductor

    Similarly, if two conductors are near each other carrying AC current, their resistances increase due to the proximity effect. At commercial power frequency, these effects are significant for large conductors carrying large currents, such as busbars in an electrical substation, [2] or large power cables carrying more than a few hundred amperes.