In refrigeration and air conditioning systems, the suction pressure' (also called the low-side pressure) is the intake pressure generated by the system compressor while operating. The suction pressure, along with the suction temperature the wet bulb temperature of the discharge air are used to determine the correct refrigerant charge in a system.
Where P is the power in airwatts, F is the rate per minute (denoted cu ft/min or CFM) and S is the suction capacity expressed as a pressure in units of inches of water. Some manufacturers choose to use the fraction 1 ⁄ 8.5 rather than the ASTM decimal, leading to a less than 0.25% variation in their calculations.
Matric suction: the defining trait of unsaturated soil, this term corresponds to the pressure dry soil exerts on the surrounding material to equalise the moisture content in the overall block of soil and is defined as the difference between pore air pressure, (), and pore water pressure, (). [2]
One of the methods is the instantaneous profile method, [3] where water content (or effective saturation) are determined for a series of suction pressure measurements . Due to the non-linearity of the equation, numerical techniques such as the non-linear least-squares method can be used to solve the van Genuchten parameters.
In fluid dynamics, total dynamic head (TDH) is the work to be done by a pump, per unit weight, per unit volume of fluid.TDH is the total amount of system pressure, measured in feet, where water can flow through a system before gravity takes over, and is essential for pump specification.
This usually occurs two to three days after rain or irrigation in pervious soils of uniform structure and texture. The nominal definition of field capacity (expressed symbolically as θ fc) is the bulk water content retained in soil at −33 kPa (or −0.33 bar) of hydraulic head or suction pressure.
of zero indicates the pressure is the same as the freestream pressure. C p {\displaystyle C_{p}} of one corresponds to the stagnation pressure and indicates a stagnation point . the most negative values of C p {\displaystyle C_{p}} in a liquid flow can be summed to the cavitation number to give the cavitation margin.
Suction is the day-to-day term for forces experienced by objects that are exposed to the movement of gases or liquids moving along a pressure gradient. Contrary to popular belief, however, the forces acting in this case do not originate from the lower pressure side (the vacuum), but from the side of the higher pressure.