Pile integrity testing using low-strain tests such as the TDR (Transient Dynamic Response) method, is a rapid way of assessing the continuity and integrity of concrete piled foundations. The test measures: pile length, or depth to anomalies; pile head stiffness; pile shaft mobility, which is dependent on pile section and concrete properties
Crosshole sonic logging (CSL) is a method to determine the structural integrity of drilled shafts and other concrete piles. The CSL method is considered to be more accurate than sonic echo testing in the determination of structural soundness of concrete within the drilled shaft inside of the rebar cage.
It is standardized by ASTM D7949 - Standard Test Methods for Thermal Integrity Profiling of Concrete Deep Foundations. The testing method was first developed in the mid 1990s at the University of South Florida. [1] [2] It relates the heat generated by curing of cement to the integrity and quality of drilled shafts, augered cast in place (ACIP ...
Ultrasonic testing is often performed on steel and other metals and alloys, though it can also be used on concrete, wood and composites, albeit with less resolution. It is used in many industries including steel and aluminium construction, metallurgy, manufacturing, aerospace , automotive and other transportation sectors.
Foundation integrity testing is the non-destructive testing of piled foundations.It was first used in the late 1960s, and has been developed over time by many companies. Three organizations supply a majority of the test equipment in use: CEBTP (Centre Expérimental de Recherches et d'Etudes du Bâtiment et des Travaux Publics) in Europe; Integrity Testing in Asia and Australia: and by GRL ...
Dynamic load testing takes a further step in analyzing the data and computing static capacity and resistance distribution. Dynamic pile monitoring takes advantage of the fact that, for driven piles, it is possible to compute the energy delivered to the pile, compression stresses at the pile top and toe and tension stresses along the shaft.
On construction sites, prior to the erection of a building, static load testing may use a large number of kentledge stacked onto a platform. This platform is used to drive piles into the ground beneath to test the integrity of the foundation. [1] [2]
A procedure for ultrasonic testing is outlined in ASTM C597 - 09. [9]In India, till 2018 ultrasonic testing was conducted according to IS 13311-1992.From 2018, procedure and specification for Ultrasonic pulse velocity test is outlined in IS 516 Part 5:Non destructive testing of concrete Section 1:Ultrasonic Pulse Velocity Testing.